•FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
•SeeChapter7“Partslisting,RS210Types6531,6532,6533,and6534”onpage175todeterminewhich
componentsarecustomerreplaceableunits(CRU)andwhichcomponentsareeldreplaceableunits(FRU).
•Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlyby
atrainedservicetechnician.
TheProcessorCPUnStatushas
FailedwithFRB1/BISTcondition.(n=
microprocessornumber)
Error
Aprocessorfailed-
FRB1/BISTconditionhas
occurred.
1.Checkforaserverrmware
update.
Important:Somecluster
solutionsrequirespeciccode
levelsorcoordinatedcode
updates.Ifthedeviceispart
ofaclustersolution,verify
thatthelatestlevelofcode
issupportedforthecluster
solutionbeforeyouupdatethe
code.
2.(Trainedservicetechnician
only)Reseatmicroprocessor
n.
3.(Trainedservicetechnician
only)Replacemicroprocessor
n.
(n=microprocessornumber)
TheProcessorCPUnStatushas
aCongurationMismatch.(n=
microprocessornumber)
Error
Aprocessorconguration
mismatchhasoccurred.
1.(Trainedservicetechnician
only)Replacethe
microprocessor.
AnSMBIOSUncorrectableCPU
complexerrorforProcessor
CPUnStatushasasserted.(n=
microprocessornumber)
Error
AnSMBIOSuncorrectable
CPUcomplexerrorhas
asserted.
1.Checkforaserverrmware
update.
Important:Somecluster
solutionsrequirespeciccode
levelsorcoordinatedcode
updates.Ifthedeviceispart
ofaclustersolution,verify
thatthelatestlevelofcode
issupportedforthecluster
solutionbeforeyouupdatethe
code.
2.(Trainedservicetechnician
only)Reseatmicroprocessor
n.
3.(Trainedservicetechnician
only)Replacemicroprocessor
n.
(n=microprocessornumber)
Chapter4.Diagnostics29