Hot-swaphard-disk-drivestatusLEDs
Eachhot-swapharddiskdrivehastwostatusLEDsonthefront.
Figure18.Hot-swaphard-disk-drivestatusLEDs
1Hard-disk-driveactivityLED2Hard-disk-driveRAIDstatusLEDDescription
OffOff
Theharddiskdrivehasfailedoris
notpresent.
On,greenOff
Theharddiskdriveispresentbutnot
inuse.
Blinking,green
Off
Theharddiskdriveisactiveanddata
isbeingtransferred.
On,greenBlinkingrapidly(aboutfourflashes
persecond),amber
TheRAIDcontrollerisidentifyingthe
harddiskdrive.
On,greenOn,amber
TheRAIDarrayhasfailedandcannot
berecovered.Youneedtorecreate
anarray.
Blinking,green
Blinkingslowly(aboutoneflashper
second),amber
Theharddiskdriveisbeingrebuilt.
RAIDcard
ThistopicprovidesinformationtohelpyoulocatetheconnectorsonaRAIDcardifaRAIDcardisinstalled
ontherisercardassembly2.
SomeservermodelscomewithaRAIDcardtoprovideadvancedSATA/SAShardwareRAIDfunctionstothe
server.Formoreinformation,referto“InstallingorremovingtheRAIDcard”onpage90.
Note:TheoptionkitfortheRAIDcardisdesignedfordifferenttypesofserversandmightcontainadditional
cablesthatarenotrequiredforyourserver.
YourserversupportsthefollowingRAIDcards:
•ThinkServerRAID500Adapter(alsoknownasThinkServer9240-8iRAID0/1Adapter)
•ThinkServerRAID700Adapter(alsoknownasThinkServer9260-8iSASRAIDAdapter)
•ThinkServerRAID710Adapter(alsoknownas9270CV-8iRAIDadapter)
30ThinkServerRD340UserGuideandHardwareMaintenanceManual