Replacing a cooling fan
The SMC - Storage Array has ten fans in its cooling cage to ensure proper cooling
of the system. Each cooling fan can be individually replaced.
To replace a cooling fan, do the following:
CAUTION:
The enclosure cover should only be removed by qualified service personnel as it
provides access to a service area. Potential hazards include:
v Energy hazard
v Rotating fans
v Hot surfaces
v Access to PSU openings
Important:
After completing the fan replacement, be sure the enclosure cover is
properly closed and securely latched by turning the lock mechanism to the
locked position.:
1. Observe all safety and ESD precautions in the Safety and Warranty Guide.
2. Release the enclosure cover by using a flat-head screwdriver to turn the lock
mechanism to the “unlocked” position (see 1 in the following figure). Slide
the cover back until it stops (see 2).
3. Remove the faulty fan by carefully lifting it up, then unplug it from the
enclosure management PCB, and remove it from the enclosure.
Figure 11. Releasing the enclosure cover
Chapter 3. Hardware installations and upgrades 15