2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaflat,
clean,andstatic-protectivesurface.SeetheRackInstallationInstructionsthatcomeswiththeserver.If
theserverisintowerformfactor,laytheserveronitssideforeasieroperation.
3.Removetheservercover.See“Removingtheservercover”onpage66.
4.Removeanypartsanddisconnectanycablesthatmightimpedeyouroperation.
5.LocatetheAnyRAIDadapterorthepass-throughboard.See“Servercomponents”onpage25.
6.DisconnectallcablesfromtheAnyRAIDadapterorthepass-throughboard.
7.Dooneofthefollowing:
•Forthepass-throughboardortheAnyRAIDadapterwithoutanairduct,gotostep8.
•For3.5-inch-driveservermodelsthathaveanAnyRAIDadapterinstalledwithanairduct
Openthesmallhandle
1bygentlypressingdownthehandleslightlyandpullingthehandleoutward
toreleaseitfromthesecuredposition.Then,lifttheAnyRAID-adapterairductstraightupandout
ofthechassis.
Figure109.RemovingtheAnyRAID-adapterairductforservermodelswith3.5-inchdrives
144ThinkServerTD350UserGuideandHardwareMaintenanceManual