
2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaflat,
clean,andstatic-protectivesurface.SeetheRackInstallationInstructionsthatcomeswiththeserver.If
theserverisintowerformfactor,laytheserveronitssideforeasieroperation.
3.Removetheservercover.See“Removingtheservercover”onpage66.
4.Removethecoolingshroud.See“Removingthecoolingshroud”onpage69.
5.Touchthestatic-protectivepackagethatcontainstheRAID110iupgradekeytoanyunpaintedsurface
ontheoutsideoftheserver.Then,taketheRAID110iupgradekeyoutofthepackage.
6.LocatetheconnectorfortheRAID110iupgradekeyonthesystemboard.Then,inserttheRAID
110iupgradekeyintotheupgradekeyconnector.EnsurethattheRAID110iupgradekeyissecurely
seatedonthesystemboard.
Figure53.InstallingtheRAID110iupgradekey
Whattodonext:
•Toworkwithanotherpieceofhardware,gototheappropriatesection.
•Tocompletetheinstallation,goto“Completingthepartsreplacement”onpage164
.Then,theonboard
SATAsoftwareRAID5isavailableforyourserverifyourserverhastherequirednumberofstoragedrives
installed.ToconfigureRAID,see“ConfiguringRAID”onpage58.
92ThinkServerTD350UserGuideandHardwareMaintenanceManual
Kommentare zu diesen Handbüchern