Pull out the mounting bracket pin 1 and slide the
mounting bracket 2 into the slide rail onto which
you are installing the cable-management arm. Push
the bracket into the slide rail until the
spring-loaded pin snaps into place.
Place the cable-management arm on the support
arm. Pull out the cable-management arm pin 1,
and then slide the cable-management arm tab 2
into the slot on the inside of the slide rail. Push the
tab until it snaps into place. Pull out the other
cable-management arm pin 3, and then slide that
cable management arm tab into the slot 4 on the
outside of the slide rail. Push the tab until it snaps
into place.
Attach the power cords and other cables to the rear
of the server (including keyboard, monitor, and
mouse cables, if required). Route the cables and
power cords on the cable-management arm 1 and
secure them with cable ties or hook-and-loop
fasteners.
Note: Allow slack in all cables to avoid tension in
the cables as the cable-management arm moves.
Slide the server into the rack until it snaps into
place. To slide the server out of the rack, press on
the release latches 1.
Note: When you move the rack cabinet, or if you
install the rack cabinet in a vibration-prone area,
insert the optional M6 screws 2 in the front of the
server.