Optimized for virtualization and database applications with maximum
memory and compute capacity in a blade
Please see the Legal Information section for important notices and information.
3.
(depending on the system configuration), for high performance and wide memory bandwidth.
The 7873 machine type supports low-voltage 1.35V DIMMs.
By scaling to 2 blade servers, the HX5 can support up to 512GB of memory—enough for even the
most demanding virtualization, database, or ERP needs. If even that’s not enough memory, using
one blade server and one memory expansion blades, the HX5 can scale to 640GB.
Alternatively, with 40 DIMM slots the server and MAX5 can be populated with inexpensive 2GB
DIMMs (for 80GB), while gaining the performance boost from using 8 memory controllers (4 in the
server and four more in the MAX5 unit).
Embedded virtualization (optional on all models) offers extremely high performance, enhanced
security, and a zero-gigabyte HDD footprint. (In other words, no mechanical HDD to fail.)
Solid state drives (SDDs) use only 2W of energy per drive, vs. 9-10W for 2.5-inch HDDs. This is as
much as 80% less energy than a HDD would use (with a corresponding reduction in heat output).
The extremely high degree of integration in the various BladeCenter chassis reduces the need for
server components, replacing numerous fans, KVM and Ethernet cables, power supplies, external
switches and other components with fewer shared hot-swap/redundant components in the
BladeCenter chassis itself. This integration also can greatly reduce the amount of power consumed
and heat produced, relative to an equivalent number of 1U servers. This can significantly reduce a
data center power bill. The reduced data center footprint can also save on infrastructure cost.
The midplanes used in all chassis provide high-speed blade-to-blade, blade-to-switch-module and
module-to-module communications internally as well as externally. The midplanes used in the
BladeCenter H and BladeCenter HT chassis provide four 10Gb data channels to each blade, and
supports high-speed switch modules, including 4X InfiniBand and 10Gb Ethernet.
The various BladeCenter chassis use ultrahigh efficiency power supplies. Most industry-standard
servers use power supplies that are between 70-75% efficient at converting power from AC wall
current to the DC power used inside servers. BladeCenter power modules are up to 92% efficient.
This helps save even more money, as more of the power input you are paying for is used for
processing, rather than released into the data center as waste heat that requires even more energy to
cool.
BladeCenter design also reduces the number of parts required to run the system. Sharing fans,
systems management, and optical media means fewer parts to buy and maintain, and fewer items
that can fail and bring the overall solution down.
Flexibility
The HX5 has the ability to grow with your application requirements, thanks to:
The ability to grow from a single-wide 2-socket server blade to a double-wide 4-socket server
configuration, optimized for compute-intensive workloads with up to 4 processors/40 cores, 512GB
of memory, 4 PCIe cards, 16 I/O ports, and 4 SSDs) in two server blades; or for memory-intensive
workloads with one server blade and one MAX5 memory expansion blade (2 processors/20 cores,
640GB of memory, 4 PCIe cards, 16 I/O ports, and 4 SSDs).
A choice of processor speeds (1.73 to 2.0GHz), and shared L3 cache sizes (12MB, 18MB, 24MB, or
30MB).
Up to two internal hot-swap 1.8-inch solid state drives, and access to terabytes of external storage
via the BladeCenter S chassis or IBM System Storage
®
SAN and NAS storage devices. SSDs
consume only 10-20% of the energy required by 2.5-inch HDDs.
Two Gigabit Ethernet ports standard, plus optional 2-port or 4-port expansion cards or a
BladeCenter PCI Express I/O Expansion Unit 3. One HX5 model includes a 10Gb expansion card
(optional in the other models).
In addition, the various BladeCenter chassis offer a high degree of flexibility:
They support configurations that are 30mm or 60mm wide, with a variety of I/O options, depending
on need.
When installed in a BladeCenter H high-speed switch bay, the optional Multi-Switch Interconnect
Module doubles the number of Gigabit Ethernet and Fibre Channel connections to every blade in
the chassis (up to 8 or 12 ports, depending on the blade server).
Xeon processor-based HX5 blades can be used in the same chassis as Intel processor-based HC10,
HS12, HS20, HS21, HS21 XM, HS22, HS22V, and HS40 blades; AMD Opteron processor-based
LS20, LS21, LS22, LS41 and LS42 blades; IBM PowerPC
®
processor-based JS20, JS21, and JS22
blades; POWER6
®
processor-based JS12, JS23, and JS43 Express blades; POWER7
®
processor-
based PS700, PS701, and PS702 blades; Cell Broadband Engineprocessor-based QS21; and
IBM PowerXCellprocessor-based QS22 blades. Depending on the blade servers used, the
various BladeCenter chassis support Microsoft Windows, Linux, Novell Netware, IBM AIX
®
and
Sun Solaris 10 operating systems in the same chassis.
Most HS/LS/JS/QS blade servers ever released by IBM are supported in every BladeCenter chassis