High-performance blade server optimized for virtualization
Please see the Legal Information section for important notices and information.
12.
chassis (for example, government/military or telecom), BladeCenter T offers special features
optimized for those environments. (HS22V is not supported in the BladeCenter T.) The next-
generation BladeCenter HT is a high-performance ruggedized telecommunications platform,
also supporting 10Gb fabrics. There is a high degree of interchangeability and compatibility of
features among the chassis. All of these chassis can be installed in a rack along with other rack-
optimized equipment. See the separate BladeCenter Chassis Sales Guide for details.
Hot-Swap/Redundant Components
System availability is maximized through the extensive use of hot-swap and redundant
components, both in the blade server and in the various BladeCenter chassis, including:
Redundant memory protection (with Chipkill error correction and memory mirroring or memory
sparing enabled)
Hot-swap, redundant hard disk drives (in BladeCenter S) and solid-state drives (with RAID
protection)
Hot-swap, redundant power supply modules
Hot-swap, redundant cooling fan/blower modules
Hot-swap, redundant switch modules
Redundant midplane connectors between blades and modules
Energy-Smart Features
IBM servers work hard to keep your energy bills low—from high-efficiency power supplies and
fans to lower-draw processors and memory. Technologies such as these, along with the Xeon
5500/5600 series processors that intelligently adjust their voltage and frequency, help take costs
out of IT:
40W 4-core processors use 50% less energy than 80W processors and 69% less than 130W
processors.
60W 6-core processors use 37% less energy than 95W processors and 54% less than 130W
processors.
1.5V DDR3 DIMMs consume 10-15% less energy than 1.8V DDR2 DIMMs used in older servers.
1.35V DDR3 DIMMs consume up to 19% less energy than 1.5V DDR3 DIMMs.
Solid-State Drives consume up to 80% less energy than 2.5-inch HDDs and up to 88% less than
3.5-inch HDDs.
Operating at as much as 94% efficiency, high efficiency power supplies use less energy than
competitive power supplies that average only 70-80% efficiency, and produce less waste heat that
needs to be cooled.
Dynamic fan speedsIn the event of a fan failure, the other fans will run faster to compensate until
the failing fan is replaced. Competitive fans must run faster at all times, just in case, wasting power.
Extensive System Support Features
The IBM services and technical support portfolio provides world-class, consistent, high-quality
service and support. From the start, IBM programs make it easier for you to plan for, configure
and purchase BladeCenter servers, get them running and keep them running long-term. These
features include IBM ServerProven, IBM Standalone Solutions Configuration Tool, IBM System x
and BladeCenter Power Configurator, IBM ServerGuide, IBM Systems Director Service and
Support Manager, Product Customization er-Services and extensive technical support offerings.
The IBM ServerProven program provides the confidence that specific options and operating
systems have been tested on the blade servers and chassis and are officially supported to work
together. It is updated frequently to keep the latest compatibility information at your fingertips.
The IBM Standalone Solutions Configuration Tool (SSCT) is a downloadable tool that
simplifies the often complex chore of configuring a full rack of servers (including blade servers)
and confirming that you have all the cables, power distribution units, KVM (keyboard, video and
mouse) switch boxes and other components you need, as well as the proper airflow clearances,
electrical circuits and other environmental conditions.
IBM System x and BladeCenter Power Configurator helps IT managers plan for data center
power needs, by providing the following information for specific configurations of System x and
BladeCenter systems: power input (watts), PDU sizing (amps), heat output (BTUs), airflow
requirements through chassis (CFM), VA rating, leakage current (mA), and peak inrush current
(amps).
IBM ServerGuide (installed from CD) simplifies the process of installing and configuring System
x servers. ServerGuide goes beyond mere hardware configuration by assisting with the
automated installation of the Microsoft
®
Win
dows
®
Server 2008 operating system, device drivers