Lenovo Px6-300d Bedienungsanleitung Seite 53

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 164
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 52
Adding iSCSI Drives
To add an iSCSI drive:
1. From the px6-300d Management Console, click iSCSI.
2. When the iSCSI page opens, click the switch to enable the feature.
3. Click Add an iSCSI drive.
4. If your px6-300d has multiple Storage Pools, select the desired Storage Pool from the drop-down
menu.
5. Enter a name for the iSCSI drive.
6. Enter a size for the iSCSI drive. The size must be smaller than the free space available on your
px6-300d.
7. Click Create to create the iSCSI drive.
Enabling iSCSI Drives
1. Click Settings to begin configuring an iSCSI drive.
2. To set the discovery of the iSCSI drive using iSNS, check Enable discovery with iSNS.
3. Choose one of the following options:
Use local iSNS server the device acts as an iSNS server for the iSCSI drives.
Use external iSNS server — you supply the IP address or host name of the external iSNS
server for the iSCSI drives.
4. To enable the Challenge Handshake Authentication Protocol (CHAP), check Enable two-way
authentication (Mutual CHAP). With Mutual CHAP enabled, the client performs an additional
check to confirm that it is using the correct device.
5. Enter an initiator secret (password) for Device Secret and then enter it again in the confirm box.
6. Click Apply to save your changes.
Connecting to iSCSI Drives
You can connect iSCSI drives on your px6-300d to your computer using LenovoEMC Storage Manager or
the Microsoft software initiator. If you are using another type of software or hardware initiator, you must
use the native tools provided with your initiator to connect your iSCSI drives. Do not connect more than
one iSCSI initiator at a time to an iSCSI drive.
Attempting to connect two iSCSI initiators to the same iSCSI drive at the same time may result in
data corruption or drive damage. The px6-300d Management Console prevents you from
connecting two iSCSI initiators to the same iSCSI drive at the same time, but if you connect to an
iSCSI drive using native tools, you may encounter this issue. You can use the Connected
Clients section to view a list of client computers connected to your px6-300d that are running
iSCSI initiator software. On the iSCSI page, expand an iSCSI drive, then expand the Connected
Clients section. If the iSCSI drive is in use, you will see a list of connected client computers
running initiator software.
iSCSI: Creating IP-Based Storage Area Networks (SAN)
Adding iSCSI Drives 43
Seitenansicht 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 163 164

Kommentare zu diesen Handbüchern

Keine Kommentare