Lenovo 59P5107 Datenblatt Seite 99

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 102
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 98
Low Voltage Intel
®
Xeon
Processor at 1.60 GHz, 2.0 GHz and 2.4 GHz
Datasheet 99
8.0 Debug Tools Specifications
The Debug Port design information has been moved. This includes all information necessary to
develop a Debug Port on this platform, including electrical specifications, mechanical
requirements, and all In-Target Probe (ITP) signal layout guidelines. Please reference the
ITP700
Debug Port Design Guide
for the design of your platform.
8.1 Logic Analyzer Interface (LAI)
Intel® is working with two logic analyzer vendors to provide logic analyzer interfaces (LAIs) for
use in debugging systems. Tektronix* and Agilent* should be contacted to get specific information
about their logic analyzer interfaces. The following information is general in nature. Specific
information must be obtained from the logic analyzer vendor.
Due to the complexity of systems, the LAI is critical in providing the ability to probe and capture
system bus signals. There are two sets of considerations to keep in mind when designing a system
that may make use of an LAI: mechanical and electrical.
8.1.1 Mechanical Considerations
The LAI is installed between the processor socket and the processor. The LAI pins plug into the
socket, while the processor pins plug into a socket on the LAI. Cabling that is part of the LAI
egresses the system to allow an electrical connection between the processor and a logic analyzer.
The maximum volume occupied by the LAI, known as the keepout volume, as well as the cable
egress restrictions, should be obtained from the logic analyzer vendor. System designers must
make sure that the keepout volume remains unobstructed inside the system. Note that it is possible
that the keepout volume reserved for the LAI may differ from the space normally occupied by the
processor heatsink. When this is the case, the logic analyzer vendor may provide a cooling solution
as part of the LAI.
8.1.2 Electrical Considerations
The LAI may also affect the electrical performance of the system bus; therefore, it is critical to
obtain electrical load models from each of the logic analyzers to be able to run system level
simulations to prove that their tool may work in the system. Contact the logic analyzer vendor for
electrical specifications and load models for the LAI solution they provide.
Seitenansicht 98
1 2 ... 94 95 96 97 98 99 100 101 102

Kommentare zu diesen Handbüchern