DiagnosticErrorCodeFRU/Action
025-00X-XXX025-01X-XXXIDEinterfacefailure
1.IDEsignalcable
2.Checkpowersupplyvoltages
3.ReseatIDEsignalcable
4.IDEdevice
5.Systemboard
025-027-XXXIDEinterfaceConguration/Setuperror
1.IDEsignalcable
2.Flashthesystem.See“Updating(ashing)BIOS
fromadisc”onpage560
3.ReseatIDEsignalcable
4.IDEdevice
5.Systemboard
025-02X-XXX025-03X-XXX025-04X-XXXIDEInterface
failure
1.IDEsignalcable
2.Checkpowersupply
3.ReseatIDEsignalcable
4.IDEdevice
5.Systemboard
025-195-XXXIDEinterfaceTestabortedbyuserInformationonlyRe-startthetest,ifnecessary
025-196-XXXIDEinterfacetesthalt,errorthreshold
exceeded
1.PressF3toreviewthelogle
2.Re-startthetesttoresetthelogle
025-197-XXXIDEinterfacetestwarning
1.Makesurethecomponentthatiscalledoutis
connectedand/orenabled.SeeChapter6“Using
theSetupUtility”onpage43
2.Re-runtest
3.Replacethecomponentthatiscalledoutinwarning
statement
4.Replacethecomponentundertest
025-198-XXXIDEinterfacetestaborted
1.Ifacomponentiscalledout,makesureitis
connectedand/orenabled.SeeChapter6“Using
theSetupUtility”onpage43
2.Flashthesystemandre-test.See“Updating
(ashing)BIOSfromadisc”onpage560
3.Goto“Undeterminedproblems”onpage69
025-199-XXXIDEinterfacetestfailed,causeunknown
1.Goto“Undeterminedproblems”onpage69
2.Flashthesystemandre-test.See“Updating
(ashing)BIOSfromadisc”onpage560
3.Replacecomponentunderfunctiontest
030-000-XXXSCSIinterfaceTestPassed
Noaction
030-00X-XXX030-01X-XXXSCSIinterfacefailure1.SCSIsignalcable
2.Checkpowersupply
3.SCSIdevice
4.SCSIadaptercard,ifinstalled
5.Systemboard
58ThinkCentreHardwareMaintenanceManual