Seite 1 - Hard ware Maintenan ce Manual

ThinkServer TS100 Types 6431, 6432, 6433, and 6434Hard ware Maintenan ce Manual

Seite 2

Guidelines for trained service techniciansThis section contains information for trained service technicians.Inspecting for unsafe conditionsUse the in

Seite 3

To remove a hot-swap power supply, complete the following steps:1. Read the safety information that begins on page vii and “Installation guidelines”on

Seite 4

Installing a hot-swap power supplyThis procedure applies only to server models that have hot-swap power supplies.See “Installing a non-hot-swap power

Seite 5 - Contents

Removing a memory moduleTo remove a dual inline memory module (DIMM), complete the following steps:1. Read the safety information that begins on page

Seite 6

Installing a memory moduleNote: If you are replacing a faulty DIMM, make sure that the replacement DIMM isthe correct type of memory. If you are addin

Seite 7 - Contents v

Removing and replacing optional-service CRUsYou may install an optional-service CRU yourself or request Lenovo to install it, atno additional charge,

Seite 8

Statement 2:CAUTION:When replacing the lithium battery, use only the battery recommended by themanufacturer. If your system has a module containing a

Seite 9

Removing the rear system fanAttention:v Replace a failed fan within 48 hours.v To ensure proper cooling and airflow, do not operate the server for mor

Seite 10

Installing the rear system fanAttention:v Replace a failed fan within 48 hours.v To ensure proper cooling and airflow, do not operate the server for m

Seite 11 - Safety ix

Removing the hard disk drive fan assemblyThis procedure applies only to server models that have a hard disk drive fanassembly.Attention:v Replace a fa

Seite 12 - Safety statements

8. Remove the cable from the slot 2 on the hard disk drive fan assembly; then,rotate the assembly away from the drive cage and remove the assembly f

Seite 13 - Safety xi

Guidelines for servicing electrical equipmentObserve the following guidelines when you service electrical equipment:v Check the area for electrical ha

Seite 14

Installing the hard disk drive fan assemblyThis procedure applies only to server models that have a hard disk drive fanassembly.Attention:v Replace a

Seite 15 - Safety xiii

2. Route the hard disk drive signal and power cables through the slots2 on theedge of the hard disk drive fan assembly3. Make sure that the cables

Seite 16

11. Lift the simple-swap backplate out of the lower lip on the drive cage and set itaside.12. If you are instructed to return the simple-swap backplat

Seite 17 - Safety xv

Installing the simple-swap backplateThis procedure applies only to server models with the simple-swap SATA backplateinstalled on the back of the hard

Seite 18 - CAUTION:

Removing the SAS/SATA hard disk drive backplaneThis procedure applies only to hot-swap server models with a SAS/SATA hard diskdrive backplane installe

Seite 19 - Chapter 1. Introduction

11. Lift the SAS/SATA hard disk drive backplane out of the lower lip on the drivecage and set it aside.12. If you are instructed to return the SAS/SAT

Seite 20

11. Reconnect the external cables and power cords; then, turn on the attacheddevices and turn on the server.98 ThinkServer TS100 Types 6431, 6432, 643

Seite 21 - Features and specifications

Removing the front-panel assemblyTo remove the front-panel assembly, complete the following steps:1. Read the safety information that begins on page v

Seite 22

Installing the front-panel assemblyTo install the front-panel assembly, complete the following steps:1. Position the front end of the front-panel asse

Seite 23 - Front view

8. Squeeze the spring clips 1 on the sides of the front USB connectorassembly and pull the assembly out of the back of the housing.9. Carefully pull

Seite 24

Safety statementsImportant:Each caution and danger statement in this document is labeled with a number. Thisnumber is used to cross reference an Engli

Seite 25 - Rear view

Rear adapterretentionbracketHinge pin6. If necessary, remove the Remote Supervisor Adapter II SlimLine retention taband store it for future use.Instal

Seite 26 - Server power features

Installing the front adapter-retention bracketTo install the front adapter-retention bracket, complete the following steps:1. Insert one of the hinge

Seite 27 - Chapter 1. Introduction 9

Removing the hot-swap power supply cageThis procedure applies only to server models that have hot-swap power-supplies.To remove the power supply cage,

Seite 28 - Connectors, LEDs, and jumpers

Installing the hot-swap power supply cageThis procedure applies only to server models that have hot-swap power-supplies.To install the hot-swap power

Seite 29 - Chapter 1. Introduction 11

Removing the mini-SAS/SATA controllerTo remove the mini-SAS/SATA RAID controller, complete the following steps:1. Read the safety information that beg

Seite 30 - Line connector

Installing the SAS/SATA controllerTo install the SAS/SATA RAID controller, complete the following steps:1. Touch the static-protective package that co

Seite 31 - System board LEDs

6. Disconnect the mini-PCI-X enablement card from the mini-PCI-X enablementcard connector ; then, grasp the edges of the mini-PCI-X enablement card an

Seite 32 - System board jumpers

3. Install and lock the side cover (see “Installing the side cover” on page 63).4. Reconnect the external cables and power cords; then, turn on the at

Seite 33 - Chapter 1. Introduction 15

Installing the RAID-MR10i SAS/SATA controllerSome server models come with a IBM ServeRAID-MR10i SAS/SATA controller. TheServeRAID-MR10i SAS/SATA contr

Seite 34

1 Hard disk drive cable connectors4-7 4 ServeRAID-MR10i SAS/SATAcontroller2 Hard disk drive cable connectors0-3 5 Hard disk drive cables4-73

Seite 35 - Configuring the server

Statement 1:DANGERElectrical current from power, telephone, and communication cables ishazardous.To avoid a shock hazard:v Do not connect or disconnec

Seite 36

pinched between the hard disk drive fan assembly and the hard disk drivebackplane when the assembly is installed.c. Rotate the hard disk drive fan ass

Seite 37

1 Remote Supervisor Adapter II SlimLine adapter2 Remote Supervisor Adapter II SlimLine retention clip3 Remote Supervisor Adapter II SlimLine sup

Seite 38

Attention: Incomplete insertion might cause damage to the system board orthe adapter.8. Press the Remote Supervisor Adapter II SlimLine adapter 1 fi

Seite 39

Removing and replacing FRUsField replaceable units (FRUs) must be installed only by trained service technicians.Removing a non-hot-swap power supplyTh

Seite 40

To remove a non-hot-swap power supply, complete the following steps:1. Read the safety information that begins on page vii and “Installation guideline

Seite 41 - Using passwords

Installing a non-hot-swap power supplyThis procedure applies only to server models that have a non-hot-swap powersupply. See “Installing a hot-swap po

Seite 42 - EasyStartup overview

Removing the microprocessor and fan sinkTo remove the microprocessor and fan sink, complete the following steps:1. Read the safety information that be

Seite 43

c. Tip the top of the fan sink toward the front of the server while you slide itaway from the lower flange of the retention module; then, remove it fr

Seite 44

Installing a microprocessor and fan sinkTo install the microprocessor, complete the following steps:1. Touch the static-protective package that contai

Seite 45

5. Close the microprocessor bracket frame 2; then, close the microprocessorretention latch 1 and lock it securely in place.6. Install the fan sink

Seite 46

Statement 2:CAUTION:When replacing the lithium battery, use only the battery recommended by themanufacturer. If your system has a module containing a

Seite 47 - Using the Boot Menu program

v Additional thermal grease is not added to the existing thermal grease on the fansink and microprocessor.Note:v Read the Safety information on page v

Seite 48

Removing the system boardTo remove the system board, complete the following steps:1. Read the safety information that begins on page vii and “Installa

Seite 49 - Formatting a hard disk drive

System boardmounting screws(8 places)Fan-sink mountingbracket slots10. Slide the system board toward the front of the server to disengage the tabs ont

Seite 50 - Requirements

12. If you are instructed to return the system board, follow all packaginginstructions, and use any packaging materials for shipping that are supplied

Seite 51

3. Insert the system board into the chassis and slide it toward the rear of theserver until the tabs on the fan sink mounting bracket is fully engaged

Seite 52

4. Install the eight screws 2 that secure the system board to the chassis.5. Reinstall the Remote Supervisor Adapter II SlimLine support bracket 1

Seite 53 - Completing the setup

v Microprocessor and fan sink (see “Installing a microprocessor and fan sink”on page 120).v Adapters (see “Installing an adapter” on page 69).7. Press

Seite 54

Chapter 5. DiagnosticsThis chapter describes the diagnostic tools that are available to help you solveproblems that might occur in the server.If you c

Seite 55 - 6431, 6432, 6433, and 6434

POST beep codesA beep code is a combination of short or long beeps or series of short beeps thatare separated by pauses. For example, a “1-2-3” beep c

Seite 56 - Replaceable server components

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 57

Statement 3:CAUTION:When laser products (such as CD drives, DVD drives, fiber optic devices, ortransmitters) are installed, note the following:v Do no

Seite 58

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 59

Error logsThe server generates three error logs:v POST error logThis log contains the three most recent error codes and messages that weregenerated du

Seite 60

For information about using the diagnostic programs, see “Running the diagnosticprograms” on page 164.To view the BMC system-event log that is generat

Seite 61

POST error codesThe following table describes the POST error codes and suggested actions tocorrect the detected problems.v Follow the suggested action

Seite 62

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 63

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 64

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 65

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 66

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 67

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 68

Statement 4:≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb)CAUTION:Use safe practices when lifting.Statement 5:CAUTION:The power control button

Seite 69 - Power cords

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 70

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 71

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 72

Checkout procedureThe checkout procedure is the sequence of tasks that you should follow todiagnose a problem in the server.About the checkout procedu

Seite 73

Performing the checkout procedureTo perform the checkout procedure, complete the following steps:1. Is the server part of a cluster?v No: Go to step 2

Seite 74

Troubleshooting tablesUse the troubleshooting tables to find solutions to problems that have identifiablesymptoms.If you cannot find the problem in th

Seite 75 - Installation guidelines

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 76 - System reliability guidelines

General problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3,

Seite 77

Intermittent problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapte

Seite 78

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 79 - Connecting the cables

Statement 8:CAUTION:Never remove the cover on a power supply or any part that has the followinglabel attached.Hazardous voltage, current, and energy l

Seite 80 - Removing the side cover

Memory problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “

Seite 81 - Installing the side cover

Microprocessor problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chap

Seite 82 - Removing the lower bezel

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 83 - Installing the lower bezel

Optional-device problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Cha

Seite 84 - Removing the upper bezel

Power problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “P

Seite 85 - Installing the upper bezel

Serial port problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter

Seite 86 - Removing an adapter

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 87 - Installing an adapter

Universal Serial Bus (USB) port problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis

Seite 88 - 3 Adapter

Error LEDsThe following illustration shows the system boardoard LEDs. The system board haserror LEDs that will help to locate the source of the error.

Seite 89

If an error occurs, view the server LEDs in the following order:1. Check the front-panel assembly on the front of the server. If the system-errorLED i

Seite 90 - Removing a CD or DVD drive

Statement 15:CAUTION:Make sure that the rack is secured properly to avoid tipping when the serverunit is extended.xvi ThinkServer TS100 Types 6431, 64

Seite 91 - Installing a CD or DVD drive

The following table describes the problems that are indicated by variouscombinations of the power supply LEDs and the power-on LED on the frontinforma

Seite 92 - Removing a tape drive

Diagnostic programs and messagesThe diagnostic programs are the primary method of testing the major componentsof the server. The diagnostic tools prov

Seite 93 - Installing a tape drive

Running the diagnostic programsImportant: The diagnostic programs do not support USB CD-ROM drives. If yourun the diagnostic programs while any USB CD

Seite 94 - 1 EMC shield 3 Tape drive

Aborted: The test could not proceed because of the server configuration.Viewing the test logYou can use one of the following methods to access the tes

Seite 95

Table 12. Diagnostic messagesv Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.v S

Seite 96 - (in open position)

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 97

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 98

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 99

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 100

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 101 - 2 Hot-swap power supply

Chapter 1. IntroductionThis Hardware Maintenance Manual contains information to help you solveproblems that might occur in the Lenovo ThinkServer™TS10

Seite 102 - Removing a memory module

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 103 - Installing a memory module

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 104 - Installing the battery

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 105

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 106 - Removing the rear system fan

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 107

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 108

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 109

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 110

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 111

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 113

information about those features, or technical updates might be available to provideadditional information that is not included in the server document

Seite 114 - 3 Locating pins

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 115

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 116

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 117

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 118

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 119

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 120 - Hinge pin

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 121

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 122

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 123

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 124

Features and specificationsThe following information is a summary of the features and specifications of theserver. Depending on the server model, some

Seite 125

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 126

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 127

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 128

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 129

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 130

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 131

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 132

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 133 - Removing and replacing FRUs

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 134

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 135

Table 1. Features and specificationsMicroprocessor:v Supports one Intel®Core™2 Duodual-core or Xeon®dual-core orquad-core microprocessorNote: Intel Vi

Seite 136 - 2 Fan-sink retention lever

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 137

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 138

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 139 - Thermal grease

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 140

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 141 - Removing the system board

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 142 - (8 places)

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 143 - Installing the system board

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 144

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 145

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 146

Server controls, LEDs, and powerThis section describes the controls and light-emitting diodes (LEDs) and how to turnthe server on and off.Front viewTh

Seite 147 - Chapter 5. Diagnostics

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 148 - POST beep codes

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 149 - Chapter 5. Diagnostics 131

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 150 - No-beep symptoms

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 151 - Error logs

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 152

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 153 - POST error codes

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 154

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 155 - Chapter 5. Diagnostics 137

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 156

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 157 - Chapter 5. Diagnostics 139

USB connectorsConnect USB devices to these connectors.CD-eject or DVD-eject buttonPress this button to release a CD from the CD drive or a DVD from th

Seite 158

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 159 - Chapter 5. Diagnostics 141

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 160

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 161 - Chapter 5. Diagnostics 143

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 162

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 163 - About the checkout procedure

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 164

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 165 - CD or DVD drive problems

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 166 - Diskette drive problems

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 167 - Hard disk drive problems

Table 12. Diagnostic messages (continued)v Follow the suggested actions in the order in which they are listed in the Action column until the problem i

Seite 168 - Intermittent problems

Rear viewThe following illustration shows the connectors and LEDs on the rear of the server.1 Ethernet transmit/ receive activity LED(amber)8 Seri

Seite 169 - Chapter 5. Diagnostics 151

Updating (flash-update) the BIOS code on the serverPeriodically, Lenovo makes new levels of BIOS code available on the Web. Alwayscheck http://www.len

Seite 170 - Memory problems

2. Set your removable media device as the first startup device.3. Select the removable media device that you want to boot from and move it tothe top o

Seite 171 - Monitor or video problems

12. Remove any adapters that impede access to the boot block recovery jumper(see “Removing an adapter” on page 68).13. Return the boot block recovery

Seite 172

System-error log messagesA system-error log is generated by both the Remote Supervisor Adapter II SlimLineadapter and the mini-BMC. The system-error l

Seite 173 - Optional-device problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 174 - Power problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 175 - EasyStartup problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 176 - Software problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 177 - Chapter 5. Diagnostics 159

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 178 - Error LEDs

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 179 - Power supply LEDs

Video connectorConnect a monitor to this connector.USB connectorsConnect USB devices to these connectors.Ethernet connectorUse this connector to conne

Seite 180

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 3, “Parts listing,

Seite 181 - Chapter 5. Diagnostics 163

Solving SAS problemsFor any SAS error message, one or more of the following devices might be causingthe problem:v A failing SAS device (adapter, drive

Seite 182 - Diagnostic text messages

Solving Ethernet controller problemsThe method that you use to test the Ethernet controller depends on which operatingsystem you are using. See the op

Seite 183 - Diagnostic messages

Solving undetermined problemsIf the diagnostic tests did not diagnose the failure or if the server is inoperative, usethe information in this section.

Seite 184 - Table 12. Diagnostic messages

Problem determination tipsBecause of the variety of hardware and software combinations that you canencounter, use the following information to assist

Seite 185

Appendix A. Getting help and technical assistanceIf you need help, service, or technical assistance or just want more informationabout Lenovo products

Seite 186

Calling for serviceDuring the warranty period, you can get help and information by telephone throughthe Customer Support Center.These services are ava

Seite 187

Service methods and procedures vary by country, and some services might not beavailable in all countries. International Warranty Service is delivered

Seite 188

250 ThinkServer TS100 Types 6431, 6432, 6433, and 6434: Hardware Maintenance Manual

Seite 189

Appendix B. NoticesLenovo may not offer the products, services, or features discussed in this documentin all countries. Consult your local Lenovo repr

Seite 190

on the server. While the server remains connected to ac power, one or more fansmight continue to run. To remove all power from the server, you must di

Seite 191

estimated through extrapolation. Actual results may vary. Users of this documentshould verify the applicable data for their specific environment.Trade

Seite 192

Maximum internal hard disk drive capacities assume the replacement of anystandard hard disk drives and population of all hard disk drive bays with the

Seite 193

Remarque : Cette marque s’applique uniquement aux pays de l’Union Européenneet à la Norvège.L’etiquette du système respecte la Directive européenne 20

Seite 194

Les batteries ou emballages pour batteries sont étiquetés conformément auxdirectives européennes 2006/66/EC, norme relative aux batteries et accumulat

Seite 195

Industry Canada Class A emission compliance statementThis Class A digital apparatus complies with Canadian ICES-003.Avis de conformité à la réglementa

Seite 196

Deutschland:Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit vonBetriebsmitteinDieses Produkt entspricht dem “Gesetz über die elekt

Seite 197

Taiwanese Class A warning statementChinese Class A warning statementKorean Class A warning statement258 ThinkServer TS100 Types 6431, 6432, 6433, and

Seite 198

IndexAAC power LED 7acoustical noise emissions 4adapterinstalling 69hot-plug 113Remote Supervisor Adapter II SlimLine 113removing 68advanced setup 21a

Seite 199

drivesbay 1, 2, or 3installing 73hot-swap, removing 76, 77simple-swap, removing 80simple-swap, removing 79DVD driveactivity LED 6eject button 6install

Seite 200

hard disk drive (continued)status LED 6hard disk driveshot-swap SAS or SATA, installing 77hot-swap SAS or SATA, removing 76simple-swap SATA, installin

Seite 201

Connectors, LEDs, and jumpersThe illustrations in this section show the connectors, light-emitting diodes (LEDs),and jumpers on the system board. The

Seite 202

microprocessorcache 21installing 120problems 153removing 118specifications 4mini-BMC force update jumper 14minimum configuration 245modes, Ethernet 30

Seite 203

removing (continued)memory modules 84microprocessor 118power supplyhot-swap 81non-hot-swap 115SAS/SATA controller 106SAS/SATA hard disk drive backplan

Seite 204

usingBoot Menu program 29Configuration/Setup Utility program 17EasyStartup 23IBM Configuration/Setup Utility program 19passwords 20, 23Vvideoconnector

Seite 206

Part Number: 46U0853Printed in USA(1P) P/N: 46U0853

Seite 207

System board external connectorsThe following illustration shows the external input/output (I/O) connectors on thesystem board.1 Ethernet transmit/

Seite 208

ThinkServer TS100 Types 6431, 6432, 6433, and 6434Hard ware Maintenan ce Manual

Seite 209

System board optional-devices connectorsThe following illustration shows the system board connectors for user-installableoptional devices.1 DIMM con

Seite 210

System board LEDsThe following illustration shows the LEDs on the system board.1 Boot block jumper (JP6)2 Clear CMOS jumper (JP1)3 Mini-BMC forc

Seite 211

System board jumpersThe following illustration shows the jumpers on the system board.1 Boot block jumper (JP6)2 Clear CMOS jumper (JP1)3 Mini-BM

Seite 212

Table 2. System board jumper blocks (continued)Jumper number Jumper name Jumper settingJP6 Boot block jumper (JP6)v Pins 1 and 2: Normal (default)v Pi

Seite 213

16 ThinkServer TS100 Types 6431, 6432, 6433, and 6434: Hardware Maintenance Manual

Seite 214

Chapter 2. Configuration information and instructionsThe firmware for the server is periodically updated and is available for downloadfrom the Web. Th

Seite 215

EasyStartup program detects installed hardware devices and guides you throughthe process of creating a response file and performing an unattended inst

Seite 216

For information about setting up and cabling a Remote Supervisor Adapter IISlimLine for use in an Advanced System Management (ASM) network, see“Settin

Seite 217

be configured, and the operating system will not be able to detect it (this isequivalent to disconnecting the device). If you disable the integrated S

Seite 218

Select this choice to set, change, or delete a power-on password.v Start OptionsSelect this choice to view or change the startup options. Changes in t

Seite 219

Note: Before using this information and the product it supports, read the general information in Appendix B, “Notices,” on page251, and the Warranty a

Seite 220

- BMC POST WatchdogThis option enables or disables the POST watchdog. Disabled is thedefault setting.- BMC POST Watchdog TimeoutThis option enables or

Seite 221

Down Arrow key to view the older entries, and use the Up Arrow key to viewthe newer entries. Select Clear system logs and press Enter to erase thesyst

Seite 222

v Support for multiple operating systemsv Installs the operating system and device drivers in an unattended mode to savetimev Creates a reuseable resp

Seite 223

v Sets the system date and timev Detects installed hardware devicesv Guides the network administrator through the process of creating a response filev

Seite 224

v Partition settings: This task enables you to choose the file system type anddefine the partition size.v Installation settings: This task prompts you

Seite 225

2. Enter your product number (machine type and model number) or select Serversfrom the Select your product list.3. Select Servers from the Brand list.

Seite 226

3. From a command line, type bmc_cfg and press Enter.For the program to interface with the mini-baseboard management controller, theparameters in the

Seite 227

3. Select Servers from the Brand list.4. From Family list, select ThinkServer TS100, and click Continue.5. Click Downloads and drivers to download fir

Seite 228

Enabling the Broadcom NetXtreme Gigabit Ethernet Boot AgentThe Broadcom NetXtreme Gigabit Ethernet Boot Agent is part of the BIOS. You canuse it to co

Seite 229

The integrated SAS/SATA controller with RAID capabilities supports RAID arrays.You can use the LSI Configuration Utility program to configure RAID 1 (

Seite 230

ContentsSafety ...viiGuidelines for trained service technicians ...viiiInspecting for unsafe conditions ...

Seite 231

Note: Before you format a hard disk, make sure that the disk is not part of amirrored pair.To format a drive, complete the following steps:1. From the

Seite 232

v Make sure that the server has an Internet connection, so that you can downloadsoftware and firmware from the Lenovo support Web site during the inst

Seite 233

1 Ethernet transmit/ receive activity LED(amber)8 Serial 1 (Com1) connector2 Ethernet link status LED (green) 9 Parallel connector3 Remote S

Seite 234

3. Select Servers from the Brand list.4. From Family list, select ThinkServer TS100, and click Continue.5. Click Downloads and drivers to download fir

Seite 235

36 ThinkServer TS100 Types 6431, 6432, 6433, and 6434: Hardware Maintenance Manual

Seite 236

Chapter 3. Parts listing, ThinkServer TS100 Machine Types6431, 6432, 6433, and 6434The following replaceable components are available for all models o

Seite 237

Replaceable server componentsReplaceable components are of three types:v Self-service customer replaceable unit (CRU): Replacement of self-serviceCRUs

Seite 238

Table 4. Parts listing, Types 6431 (continued)Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumber9 Hard disk d

Seite 239

Table 4. Parts listing, Types 6431 (continued)Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumber16 Microproce

Seite 240

Table 4. Parts listing, Types 6431 (continued)Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumberIBM Ultra320

Seite 241

Installing the lower bezel ...65Removing the upper bezel...66Installing the upper bezel ...67Removi

Seite 242

Table 4. Parts listing, Types 6431 (continued)Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumberFRUGBM (all m

Seite 243

Table 5. Parts listing, Types 6432Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumber1 Chassis assembly (all m

Seite 244

Table 5. Parts listing, Types 6432 (continued)Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumber11 Hard disk

Seite 245

Table 5. Parts listing, Types 6432 (continued)Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumber19 Power supp

Seite 246

Table 5. Parts listing, Types 6432 (continued)Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumberIBM SAS HBA C

Seite 247

Table 6. Parts listing, Types 6434Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumber1 Chassis assembly (all m

Seite 248

Table 6. Parts listing, Types 6434 (continued)Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumber11 Hard disk

Seite 249

Table 6. Parts listing, Types 6434 (continued)Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumber19 Power supp

Seite 250

Table 6. Parts listing, Types 6434 (continued)Index DescriptionCRU partnumber(Self-service)CRU partnumber(Optional-service)FRU partnumberIBM x RAID 10

Seite 251 - Chapter 5. Diagnostics 233

Power cordsFor your safety, Lenovo provides a power cord with a grounded attachment plug touse with this Lenovo product. To avoid electrical shock, al

Seite 252

Performing the checkout procedure ...146Troubleshooting tables ...147CD or DVD drive problems ...147Dis

Seite 253 - System-error log messages

Table 7. Power cords, Type 6431 (continued)Lenovo Power cordpart number Used in these countries and regions39M5144 Bangladesh, Lesotho, Macao, Maldive

Seite 254

Table 8. Power cords, Type 6432 (continued)Lenovo Power cordpart number Used in these countries and regions39M5123 Afghanistan, Albania, Algeria, Ando

Seite 255 - Chapter 5. Diagnostics 237

Table 8. Power cords, Type 6432 (continued)Lenovo Power cordpart number Used in these countries and regions39M5081 110 - 120 VAntigua and Barbuda, Aru

Seite 256

Table 9. Power cords, Type 6434Lenovo Power cordpart number Used in these countries and regions39M5247 Taiwan (models)39M5206 China (models 14H)39M510

Seite 257 - Chapter 5. Diagnostics 239

Table 9. Power cords, Type 6434 (continued)Lenovo Power cordpart number Used in these countries and regions39M5081 110 - 120 VAntigua and Barbuda, Aru

Seite 258

Chapter 4. Removing and replacing server componentsReplaceable components are of three types:v Self-service customer replaceable unit (CRU): Replaceme

Seite 259 - Chapter 5. Diagnostics 241

v If you must start the server while the cover is removed, make sure that no one isnear the server and that no other objects have been left inside the

Seite 260

Working inside the server with the power onAttention: Static electricity that is released to internal server components whenthe server is powered-on m

Seite 261 - Solving power problems

Handling static-sensitive devicesAttention: Static electricity can damage the server and other electronic devices.To avoid damage, keep static-sensiti

Seite 262

Connecting the cablesYou must turn off the server before you connect any cables to or disconnect anycables from the server.Note: If the cable that you

Seite 263 - Solving undetermined problems

Taiwanese Class A warning statement ...258Chinese Class A warning statement ...258Korean Class A warning statement ...

Seite 264 - Problem determination tips

Removing and replacing self-service CRUsReplacement of self-service CRUs is your responsibility. If Lenovo installs aself-service CRU at your request,

Seite 265 - Using the documentation

Installing the side coverAttention: For proper cooling and airflow, replace the side cover before you turnon the server. Operating the server for exte

Seite 266 - Using other services

Removing the lower bezelWhen you work with some devices, such as the drives in bays 4 through 7 (or bays4 through 11 for some 2.5 inch hard disk drive

Seite 267 - Lenovo Taiwan product service

Installing the lower bezelTo install the lower bezel, complete the following steps:1. Insert the two bottom tabs on the lower bezel into the correspon

Seite 268

Removing the upper bezelWhen you work with some devices, such as the drives in bays 1 through 3, youmust first remove the upper bezel to access the de

Seite 269 - Appendix B. Notices

Installing the upper bezelTo install the upper bezel, complete the following steps:1. Insert the two tabs on the right-side of the upper bezel into th

Seite 270 - Important notes

Removing an adapterTo remove an adapter, complete the following steps:1. Read the safety information that begins on page vii and “Installation guideli

Seite 271 - Appendix B. Notices 253

2 Rear adapter retention bracket 5 Left side of the Front adapterretention bracket3 Expansion-slot screw 6 Right side of the Front adapterrete

Seite 272 - Battery return program

the adapter with the expansion slot guides; then, press the adapter firmly intothe expansion slot. For a full-length adapter, make sure that the front

Seite 273 - Electronic emissions notices

Removing and installing internal drivesSee the User Guide for information about the types of drives that the serversupports and other important inform

Seite 274

SafetyBefore installing this product, read the Safety Information.Antes de instalar este produto, leia as Informações de Segurança.Pred instalací toho

Seite 275 - Appendix B. Notices 257

Removing a CD or DVD driveTo remove a CD or DVD drive, complete the following steps:1. Read the safety information that begins on page vii and “Instal

Seite 276

Installing a CD or DVD driveTo install a CD or DVD drive, complete the following steps:1. If you are replacing a removed drive with a new drive, make

Seite 277

3. Follow the instructions that come with the drive to set jumpers or switches, ifthere are any.Note: You might find it easier to install the new driv

Seite 278

7. Press and hold the blue release button on the side of the bay to release thedrive; then, pull the drive out of the front of the server.8. Remove th

Seite 279 - Index 261

8. Set any jumpers or switches on the drive according to the documentation thatcomes with the drive.9. Remove the drive retainer clip from the side of

Seite 280

1. Read the safety information that begins on page vii and “Installation guidelines”on page 57.Note: You do not have to turn off the server to remove

Seite 281 - Index 263

Server model with four hot-swap drivebaysServer model with eight hot-swap drivebaysDrive-trayassemblyDrive tray handle(in open position)Drive-trayasse

Seite 282

Removing a simple-swap hard disk driveThis procedure applies only to server models that have simple-swap SATA hard diskdrives.Attention: Simple-swap h

Seite 283

Installing a simple-swap hard disk driveThis procedure applies only to server models that have simple-swap SATA hard diskdrives. See the User Guide fo

Seite 284 - (1P) P/N: 46U0853

Removing a hot-swap power supplyThis procedure applies only to server models that have hot-swap power supplies.See “Removing a non-hot-swap power supp