Lenovo 70F10002UK Datenblatt

Stöbern Sie online oder laden Sie Datenblatt nach Festplatten-Arrays Lenovo 70F10002UK herunter. Lenovo ThinkServer SA120 Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 1
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
ThinkServer SA120 Platform Specification
Product Specifications Reference (PSREF)
LenovoSee footnotes for more detailed information
Connection mode Connects directly to host server, up to 4 enclosures per port (cascading mode)
Compatible
host server and
RAID controllers/Host
Bus adapters
Supports the following RAID controller or Host Bus adapters
on compatible host servers,
RAID levels are supported by RAID controller on host server:
RAID/HBA adapters PN
TD340
RD340
RD440
RD540
RD640
RD330
RD430
RD530
RD630
LSI 9280-8e 6Gb SAS RAID HBA by LSI
(0/1/10/5/50/6/60)
4XB0F28645 Ye s Ye s
LSI 9286CV-8e 6Gb SAS RAID HBA by LSI
(0/1/10/5/50/6/60)
4XB0F28646 Ye s
I/O Module
Supports 1 or 2 ThinkServer Storage Array 6Gbps I/O Modules,
redundant with two I/O modules
Front 3.5" Disk Bays
12 x 3.5" SAS hard drive bays, hot-swap,
supports 1TB/2TB/3TB/4TB 3.5" SAS 6.0Gb/s 7200 rpm hard drives
Rear 2.5" Disk Bays
(optional)
Optional 4 x 2.5" SATA SSD hot-swap disk drive bays.
Requires optional ThinkServer 2.5" SATA SSD Cage with SATA Interposers
(4XF0F28766, includes two SSD cages for 4 bays)
Maximum storage
per enclosure
Front 3.5" Disk Bays: up to 48TB (using 12 x 4TB 3.5" SAS hard drives)
Optional rear 2.5" Disk Bays: up to 3.2TB (using 4 x 800GB 2.5" SSD drives)
External minSAS Cable
(option)
Optional 0.5m/1.0m/2.0m/4.0m/6.0m SFF8088 to SFF8088 26-pin Mini-SAS
cables
Fan module
Two fan modules standard, hot-swap, redundant, two fans per fan module
Power supply
One or two 550 watts standard, two maximum, rear access, hot-swap,
80 PLUS Gold qualified, redundant with two power supplies
Rail kit Includes static rail kit for rack mount
Systems Management
SCSI Enclosure Services (SES) command set
• Enclosure management via IOCC controller
• Includes one RS232 to RJ11 cable for remote debug and rmware upgrade
Mechanical
2U rack, static rail kit included
19"W x 15.51"D x 3.4"H (with rack handles)
482.6mm W x 394.05mm D x 86.6mm H (with rack handles)
22 kg (48.5 lb) when fully configured
Environment • Air temperature:
Operating: 10°C to 35°C (50°F to 95°F)
Storage: -40°C to 70°C (-40°F to 158°F) in original package
• Altitude: 0-10000ft (0-3048m), unpressurized
• Humidity:
Operating: 8% to 80% (non-condensing)
Storage without package: 8% to 80% (non-condensing)
Storage with package: 8% to 90% (non-condensing)
3.5" 1TB 7.2K SAS 6Gbps Hot Swap Hard Drive 0C19530
3.5" 2TB 7.2K SAS 6Gbps Hot Swap Hard Drive 0C19531
3.5" 3TB 7.2K SAS 6Gbps Hot Swap Hard Drive 0C19532
3.5" 4TB 7.2K SAS 6Gbps Hot Swap Hard Drive 4XB0F28635
3.5" 6TB 7.2K SAS 12Gbps Hot Swap Hard Drive 4XB0F28683
2.5" 100GB Mainstream Multipurpose SATA 6Gbps Hot Swap SSD 4XB0F28636
2.5" 200GB Mainstream Multipurpose SATA 6Gbps Hot Swap SSD 4XB0F28637
2.5" 400GB Mainstream Multipurpose SATA 6Gbps Hot Swap SSD 4XB0F28638
2.5" 800GB Mainstream Multipurpose SATA 6Gbps Hot Swap SSD 4XB0F28639
2.5" 120GB Value Read-Optimized SATA 6Gbps Hot Swap SSD 4XB0F28615
2.5" 240GB Value Read-Optimized SATA 6Gbps Hot Swap SSD 4XB0F28616
2.5" 300GB Value Read-Optimized SATA 6Gbps Hot Swap SSD 4XB0F28640
2.5" 480GB Value Read-Optimized SATA 6Gbps Hot Swap SSD 4XB0F28617
2.5" 800GB Value Read-Optimized SATA 6Gbps Hot Swap SSD 4XB0F28641
550W Gold Hot Swap Redundant Power Supply 4X20E54689
ThinkServer Storage Array 6Gbps IO Module 4XF0F28765
ThinkServer 2.5" SATA SSD Cage with SATA Interposers
(includes two SSD cages for 4 bays)
4XF0F28766
0.5 meters 26 Pin (SFF-8088 to SFF-8088) External mini-SAS cable 4X90F31494
1 meter 26 Pin (SFF-8088 to SFF-8088) External mini-SAS cable 4X90F31495
2 meters 26 Pin (SFF-8088 to SFF-8088) External mini-SAS cable 4X90F31496
4 meters 26 Pin (SFF-8088 to SFF-8088) External mini-SAS cable 4X90F31497
6 meters 26 Pin (SFF-8088 to SFF-8088) External mini-SAS cable 4X90F31498
Core Options
Rear
1 Power Supply 1
2/9 Fan modules
3/4/7/8 Rear 4 x 2.5" SATA SSD drive bays
(optional)
Front
5 I/O module 1
6 I/O module 2 (optional)
10 Power Supply 2 (optional)
12 x 3.5" hot-swap SAS disk drive bays
Rear Ports (per I/O module)
1 SAS (SFF8088) IN connector for connection to host server
1 SAS (SFF8088) OUT connector for connection to another enclosure
1 RJ-11 port for remote debug and firmware upgrade
Seitenansicht 0
1

Inhaltsverzeichnis

Seite 1

ThinkServer SA120 Platform SpecificationProduct Specifications Reference (PSREF)  LenovoSee footnotes for more detailed informationConnection mode Conn

Kommentare zu diesen Handbüchern

Keine Kommentare