Table 11. Abbreviated list of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
1801 A PCI or PCI Express adapter has requested
memory resources that are not available.
1. Make sure that no devices have been
disabled in the Configuration/Setup
Utility program.
2. Change the order of the adapters in the
PCI and PCI Express slots. Make sure
that the startup (boot) device is
positioned early in the scanning order.
(For information about the scanning
order, see the User Guide on the
ThinkServer Documentation DVD).
3. Make sure that the settings for the
adapter and all other adapters in the
Configuration/Setup Utility program are
correct. If the memory resource settings
are not correct, change them.
4. If all memory resources are being used,
remove an adapter to make memory
available to the adapter. Disabling the
BIOS on the adapter should correct the
error. See the documentation that comes
with the adapter.
1802 No more I/O space is available for a PCI or
PCI Express adapter.
1. If the error code indicates a particular
PCI or PCI Express slot or device,
remove that device.
2. Reseat each adapter.
3. Replace the following components one at
a time, in the order shown, restarting the
server each time:
a. Failing PCI or PCI Express adapter
b. (Trained service technician only)
System board
1803 No more memory (above 1 MB for a PCI or
PCI Express adapter).
1. If the error code indicates a particular
PCI or PCI Express slot or device,
remove that device.
2. Reseat each adapter.
3. Replace the following components one at
a time, in the order shown, restarting the
server each time:
a. Failing PCI or PCI Express adapter
b. (Trained service technician only)
System board
58 ThinkServer TS100 Types 6431, 6432, 6433, 6434: Installation Guide