Lenovo ThinkServer TD200x Bedienungsanleitung Seite 77

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 214
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 76
Installing the fan-cage assembly
1 Fan cage assembly
2 Fan cage assembly release buttons
To install the fan-cage assembly, do the following:
1. Align the guides on the fan cage with release latches on each side.
2. Push the fan-cage assembly into the server until it clicks into place.
3. If you removed any full-length PCI adapters, install them (see “Installing an
adapter” on page 72).
4. Install the air baffle (see “Installing the air baffle” on page 59).
5. Return the power-supply cage to its closed position (see “Closing the
power-supply cage” on page 49).
6. Install the hot-swap power supply or power supplies (see “Installing a hot-swap
power supply” on page 64).
7. Install and lock the left-side cover (see “Installing the side cover” on page 99).
8. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Removing the battery
To remove the battery, do the following:
1. Read the safety information that begins on page vii and “Handling
static-sensitive devices” on page 39.
2. Turn off the server and all attached devices.
3. Disconnect all external cables and power cords.
4. Turn the server on its side so that it is lying flat, with the side cover facing up.
5. Unlock and remove the left-side cover (see “Removing the left-side cover” on
page 42).
Chapter 5. Installing optional devices and replacing customer replaceable units 61
Seitenansicht 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 213 214

Kommentare zu diesen Handbüchern

Keine Kommentare