POST error codes
When you turn on the server, it performs a series of tests to check the operation of
the server components and some optional devices in the server. This series of tests
is called the power-on self-test, or POST.
If a power-on password is set, you must type the password and press Enter, when
you are prompted, for POST to run.
If POST is completed without detecting any problems, the server startup is
completed.
If POST detects a problem, an error message is sent to the POST event log.
The following table describes the POST error codes and suggested actions to
correct the detected problems. These errors can appear as severe, warning, or
informational.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the "Parts Listing" section in the Hardware Maintenance Manual to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
0010002 Microprocessor not supported
1. Reseat the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only)
Microprocessor 2 (if one is installed)
2. (Trained service technician only) Remove
microprocessor 2 and restart the server.
3. (Trained service technician only) Remove
microprocessor 1 and install microprocessor 2 in
the microprocessor 1 connector. Restart the
server. If the error is corrected, microprocessor 1
is bad and must be replaced.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only)
Microprocessor 2
c. (Trained service technician only) System
board
0011000 Invalid microprocessor type
1. Update the firmware (see “Updating the firmware”
on page 119).
2. (Trained service technician only) Remove and
replace the affected microprocessor (error LED is
lit) with a supported type.
Chapter 7. Troubleshooting 143