Installation and User GuideThinkServer TD200xMachine Types: 3719, 3821, 3822, and 3823
Antes de instalar este producto, lea la información de seguridad.Läs säkerhetsinformationen innan du installerar den här produkten.Important:Each caut
6. Close the bezel (see “Closing the bezel” on page 98).Removing a memory module1 DIMM2 Retaining clipTo remove a dual inline memory module (DIMM)
Installing a memory moduleThe following notes describe the types of dual inline memory modules (DIMMs) thatyour server supports and other information
v The server supports 1 GB, 2 GB, and 4 GB DIMMs, with a minimum of 1 GB anda maximum of 64 GB of system memory.For 32-bit operating systems only: Som
following illustration shows that the first pair of DIMMs (indicated by ones (1) insidethe boxes) should be installed in DIMM connector 3 on channel 0
1 CPU 12 CPU 2The following table lists the installation sequence for installing DIMMs inmemory-mirroring mode.Table 8. Memory-mirroring mode DIMM
The following illustration shows how to install DIMMs on the system board.Attention: Static electricity that is released to internal server components
1 DIMM2 Retaining clip10. Insert the DIMM into the connector by aligning the edges of the DIMM with theslots at the ends of the DIMM connector. Fi
2. Enter your product number (machine type and model number) or selectServers and Storage from the Select your product list.3. Select Servers and Stor
2 Microprocessor 2Attention:1. A startup (boot) microprocessor must always be installed in microprocessorsocket 1 on the system board.2. To ensure c
d. Make sure the microprocessor is oriented and aligned and positioned in thesocket before you try to close the lever.9. Install the microprocessor:a.
Statement 1:DANGERElectrical current from power, telephone, and communication cables ishazardous.To avoid a shock hazard:v Do not connect or disconnec
Attention: Do not touch the thermal grease 1 on the bottom of the heatsink 2 or set down the heat sink after you remove the plastic cover. Touchin
d. Slide the rear flange of the heat sink into the opening in the retainerbracket.e. Press down firmly on the front of the heat sink until it is seate
1 Microprocessor2 0.02 mL of thermal grease5. Use the thermal-grease syringe to place nine uniformly spaced dots of 0.02 mLeach on the top of the
4. Pull outward on the free end of the handle to remove the fan from the server.5. If you are instructed to return the hot-swap fan, follow all packag
4. Rotate the top edge of left-side cover toward the server; then, press down onthe cover handle until it clicks into place (“Installing the side cove
1 Pull pointTo close the bezel, do the following:1. Rotate the left side of the bezel toward the server to the closed position.2. Lock the left-side
1 USB 1 7 Power-error LED2 USB 2 8 dc-power LED3 USB 3 9 ac-power LED4 USB 4 10 Video5 Ethernet 10/100/1000 11 Serial 1 (COM 1)6
For information about configuring the integrated Gigabit Ethernet controller, see“Configuring the Gigabit Ethernet controller” on page 118.Chapter 5.
102 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide
Chapter 6. Configuring the serverThe following configuration programs come with the server:v Setup UtilityThe Setup Utility (formerly called the Confi
Statement 2:CAUTION:When replacing the lithium battery, use only the battery recommended by themanufacturer. If your system has a module containing a
Table 9. Server configurations and applications for configuring and managing RAIDarrays (continued)Server configurationRAID array configuration(before
Utility, the changes are reflected in the system summary; you cannot changesettings directly in the system summary.– Product DataSelect this choice to
- Network ConfigurationSelect this choice to view the system management network interface port,the IMM MAC address, the current IMM IP address, and ho
v User SecuritySelect this choice to set, change, or clear passwords. See “Passwords” for moreinformation.This choice is on the full and limited Setup
password has access to only the limited Setup Utility menu; the user can set,change, and delete the power-on password, if the system administrator has
v Change the position of the power-on password switch (enable switch 2 of thesystem board switch block (SW6)) to bypass the power-on password check (s
Using the Boot Selection Menu programThe Boot Selection Menu is used to temporarily redefine the first startup devicewithout changing boot options or
Table 10. RAID utilities (continued)RAID configurationutility Description LocationWhere to find moreinformationLSI Logic MPT SetupUtilityFor:v ServeRA
v If you install a different type of RAID controller, see the documentation thatcomes with the controller for information about viewing and changing s
8. Exit the Setup Utility.Using the WebBIOS utilityThe WebBIOS configuration utility enables you to create and manage RAIDconfigurations on LSI SAS co
Statement 3:CAUTION:When laser products (such as CD-ROMs, DVD drives, fiber optic devices, ortransmitters) are installed, note the following:v Do not
Creating a storage configuration using the Configuration WizardFollow these steps to start create a storage configuration:1. Click Configuration Wizar
Using the ThinkServer EasyStartup DVDThe ThinkServer EasyStartup DVD simplifies the process of configuring your RAIDcontroller and installing an opera
v Manually remove the drives that you do not want included in your arraybefore you configure your RAID controller through the EasyStartupprogram.This
If you continue to the main program interface, you will have the following selectableoptions:v Compatibility notes: This selection provides informatio
v Start installation: This task starts the actual installation process. First, the diskis prepared using the disk and partition information you specif
Updating the firmwareThe firmware in the server is periodically updated and is available for download onthe Lenovo Support Web site. Go to http://www.
Starting the backup server firmwareThe system board contains a backup copy area for the server firmware. This is asecondary copy of server firmware th
v Power/Reset control (power-on, hard and soft shut down, hard and soft reset,schedule power control)v Alerts (in-band and out-of-band alerting, PET t
Note: Approximately 3 minutes after the server is connected to ac power, thepower-control button becomes active.2. When the prompt <F1> Setup is
Use the command-line interface to issue setup commands. You can save any of thesettings as a file and run the file as a script. The ASU program suppor
Statement 4:≥ 18 kg (39.7 lb.) ≥ 32 kg (70.5 lb.) ≥ 55 kg (121.2 lb.)CAUTION:Use safe practices when lifting.Statement 5:CAUTION:The power control but
5. (For both Windows Server 2003 and 2008) Download Microsoft Web ServicesEnhancement 2.0 Service Pack 3 (LANDesk Process Manager only) from thefollow
4. Select the checkbox next to Web Server (IIS). A dialog box displays theadditional features that are required.5. Click Add Required Features, then c
126 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide
Chapter 7. TroubleshootingThis chapter describes the diagnostic tools that are available to help you solveproblems that might occur in the server.If y
DVD drive problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts
Hard disk drive problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the
Keyboard, mouse, or pointing-device problemsv Follow the suggested actions in the order in which they are listed in the Action column until the proble
Memory problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts li
Microprocessor problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the
Monitor problemsSome monitors have their own self-tests. If you suspect a problem with yourmonitor, see the documentation that comes with the monitor
Statement 8:CAUTION:Never remove the cover on a power supply or any part that has the followinglabel attached.Hazardous voltage, current, and energy l
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts listing in the Ha
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts listing in the Ha
Power problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts lis
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts listing in the Ha
Software problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts
2. Check for loose cables in the power subsystem. Also check for short circuits, forexample, if a loose screw is causing a short circuit on a circuit
Solving undetermined problemsIf the diagnostic tests did not diagnose the failure or if the server is inoperative, usethe information in this section.
v System-event log: This log contains all IMM, POST, and system managementinterrupt (SMI) events. You can view the system-event log through the SetupU
4. Click Downloads and drivers to download firmware updates.If IPMItool is installed in the server, you can use it to view the system-event log.Most r
POST error codesWhen you turn on the server, it performs a series of tests to check the operation ofthe server components and some optional devices in
DANGEROverloading a branch circuit is potentially a fire hazard and a shock hazardunder certain conditions. To avoid these hazards, ensure that your s
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
Chapter 1. IntroductionThis Installation and User Guide is intended to use with your Lenovo®ThinkServer™TD200x (Machine Types 3719, 3821, 3822, and 38
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
1 Model and machine typeImportant: The server keys cannot be duplicated by a locksmith. If you lose them,order replacement keys from the key manufac
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
v Danger: These statements indicate situations that can be potentially lethal orextremely hazardous to you. A danger statement is placed just before t
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the "Parts Listing&quo
Note: After you exit from the stand-alone memory diagnostic environment, youmust restart the server to access the stand-alone memory diagnosticenviron
To save the DSA log to a file on a diskette or to the hard disk, click Save Log onthe diagnostic programs screen and specify a location and name for t
Appendix A. Getting help and technical assistanceIf you need help, service, or technical assistance or just want more informationabout Lenovo products
Calling for serviceDuring the warranty period, you can get help and information by telephone throughthe Customer Support Center.These services are ava
Service methods and procedures vary by country, and some services might not beavailable in all countries. International Warranty Service is delivered
180 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide
Appendix B. NoticesLenovo may not offer the products, services, or features discussed in this documentin all countries. Consult your local Lenovo repr
estimated through extrapolation. Actual results may vary. Users of this documentshould verify the applicable data for their specific environment.Trade
Lenovo makes no representation or warranties regarding non-Lenovo products andservices, including but not limited to the implied warranties of merchan
4 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide
L’etiquette du système respecte la Directive européenne 2002/96/EC en matière deDéchets des Equipements Electriques et Electroniques (DEEE), qui déter
Battery return programThis product may contain a lithium or lithium ion battery. Consult your user manualor service manual for specific battery inform
batteries pour indiquer que la batterie ne doit pas être mise au rebut mais plutôtrécupérée en fin de cycle de vie selon cette norme.In accordance wit
This device complies with Part 15 of the FCC Rules. Operation is subject to thefollowing two conditions: (1) this device may not cause harmful interfe
Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2004/108/EG(früher 89/336/EWG) zur Angleichung der Rechtsvorschriften über dieelek
Japan Voluntary Control Council for Interference (VCCI) statementTaiwan Class A warning statementPeople’s Republic of China Class A warning statementK
190 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide
IndexAac power LED 25adapterboot option 73installing 73PCI bus, identification 73removing 72types and installation information 72administrator passwor
DIMM (continued)removing 84types and installation information 85DIMMsinstallation sequence for memory mirroring 88display problems 133documentation DV
installing (continued)bezel 46DIMM 89DVD drive 76fan-cage assembly 61fans 97hot-swap hard disk drive 83left-side cover 99microprocessor 92power supply
Chapter 2. Server setup roadmapThe installation process varies depending on the configuration of the server when itwas delivered. In some cases, the s
Ppasswordadministrator 109power-on 108PCIbus LED 19extender card slots 73slot error LEDs 32slots 72, 73POSTerror codes 143event log 140powerproblems 1
switch block 6 switches 28symmetric multiprocessing 9systemevent log 142system boardexternal connectors 27internal connectors 25LED 19LEDs 29system re
196 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide
Printed in USA
6 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide
Chapter 3. What is included with your serverThe TD200x server package includes the server, printed instructions, theThinkServer Documentation DVD, and
– Remotely accessing the server, using the keyboard and mouse from a remoteclient– Mapping the CD or DVD drive, diskette drive, and USB flash drive on
The server supports up to eight or 16 (depending on your model) 2.5-inchhot-swap hard disk drives in the hot-swap bays. With the hot-swap feature, you
Note: As of the date of this document, the Linux operating system does notsupport TOE.SpecificationsThe following information is a summary of the feat
Table 2. Features and specificationsMicroprocessor:v Intel Xeon dual-core or quad-core withintegrated memory controller and Quick PathInterconnect (QP
EasyStartupThe ThinkServer EasyStartup program simplifies the process of your RAIDcontroller and installing supported Microsoft®Windows®and Linux oper
v Integrated Ethernet controllersv Intelligent Platform Management Interface (IPMI) 2.0v Key-lock support for physical securityv Memory change message
ThinkServer TD200x Types 3719, 3821, 3822, and 3823Installation and User Guide
14 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Installation and User Guide
Chapter 4. Server controls, LEDs, and powerThis section describes the controls and light-emitting diodes (LEDs) and how to turnthe server on and off.F
Power-control button: Press this button to turn the server on and off manually. Apower-control-button shield comes with the server. You can install th
1 System power-on LED2 Hard disk drive activity LED3 System-locator LED4 System-information LED5 System-error LEDv Follow the suggested acti
1 Server processor bus 8 Power supply2 Microprocessor 9 Fan3 VRM 10 PCI bus4 Microprocessor/memory configuration 11 System board5 Me
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Parts Listing in the Ha
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Parts Listing in the Ha
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Parts Listing in the Ha
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Parts Listing in the Ha
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Parts Listing in the Ha
Note: Before using this information and the product it supports, read the general information in Appendix B, “Notices,” on page 181and the Warranty an
Rear viewThe following illustration shows the connectors and LEDs on the rear of the server.1 USB 1 7 Power-error LED2 USB 2 8 dc-power LED3
ac-power LED: Each hot-swap power supply has an ac-power LED and a dc-powerLED. When the ac-power LED is lit, it indicates that sufficient power is co
1 Microprocessor 2 21 Wake on LAN2 System power 22 Battery3 ADV power 23 PCI Express x8 slot 74 Optical power 24 PCI - 32 slot 65 Fr
System-board external connectorsThe following illustration shows the external input/output connectors and the NMIbutton on the system board.1 Video
Table 3. System-board jumpersJumpernumberJumpername Jumper setting1 JP6 UEFI bootrecoveryv Pins 1 and 2: Normal operation (default).v Pins 2 and 3:
System-board LEDsThe following illustration shows the LEDs on the system board.1 PCI slot 1 error LED 9 Battery error LED2 PCI slot 2 error LED
Express extender card 1, if one is installed.The following illustration shows the LEDs (1 and 2) on the PCI-X extender card,if one is installed.
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts listing in the Ha
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts listing in the Ha
SAS backplane connectorsThe following illustration shows the connectors on the SAS backplane.1 Hard disk drive connectors2 Power connector3 Sign
ContentsSafety ...viiChapter 1. Introduction ...1Notices and statements in this document...2R
The following table describes the problems that are indicated by variouscombinations of the power-supply LEDs and the power-on LED on the operatorinfo
provide cooling while the server is connected to power. You can turn on the serverand start the operating system by pressing the power-control button.
v If the operating system stops functioning, you can press and hold thepower-control button for more than 4 seconds to turn off the server.v The IMM c
Chapter 5. Installing optional devices and replacing customerreplaceable unitsThis chapter provides detailed instructions for installing optional hard
devices. However, you must turn off the server before performing any steps thatinvolve removing or installing adapter cables or non-hot-swap optional
v Avoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirtsbefore working inside the server; do not wear cuff links while you
Server componentsThe following illustration shows the major components in the server.1 Cover 14 USB cable/EasyLED diagnosticsassembly2 Rear adap
Opening the bezelImportant: Before you install optional hardware, make sure that the server isworking correctly. If an operating system is installed,
4. From inside of the top section of the bezel door, slide the blue tab up to unlockthe bezel media door; then, grasp the depressed area on the left s
1 Cover release latch2 Lock3 Left-side coverTo remove the cover, do the following:1. Read the safety information that begins on page vii and “In
Removing a hot-swap power supply ...63Installing a hot-swap power supply ...64Installing redundant power supply and fans .
Removing the bezel1 Bezel2 Hinge assembly3 Retention tabsTo remove the bezel, do the following:1. Read the safety information that begins on pag
4. Press the retention tabs 1 on the hinge assembly toward each other and pullthe hinge assembly out of the chassis.Note: The bezel will also diseng
Installing the bezel1 Bezel2 Hinge assembly3 Retention tabsTo install the bezel, do the following:1. Align the hinge assemblies with the hinge h
b. Align the sliding hinge mount 1 with the hinge pin 2 on the hingeassembly 3 on the chassis.c. Press the sliding hinge mount against the hinge
3. Press the release latch on the power supplies and filler panels and pull themout of the power-supply cage.1 Release latch2 Hot-swap power suppl
Closing the power-supply cageTo return the power-supply cage to its closed position, do the following:1. Rotate the power-supply cage back slightly; t
2. Carefully rotate the power-supply cage into the server chassis. The locating tabson the power-supply cage must fit over the corresponding tabs on t
4. Install and lock the left-side cover (see “Completing the installation” on page97).5. Install the hot-swap power supplies.6. Reconnect the external
3. Reinstall the feet 1 in the opposite location. The tab on the feet should extendbeyond the edge of the server.Internal cable routing and connecto
The following illustration shows the internal SAS/SATA cable routing and connectorsfrom the ServeRAID BR10i controller to eight 2.5-inch hard disk dri
Installation order ...123Installing Windows 2003 components on the Core Server...124Installing Windows 2008 32-bit components
The following illustration shows the internal SAS/SATA cable routing and connectorsfrom the ServeRAID BR10i controller to 16 2.5-inch hard disk drives
The following illustration shows the internal SAS/SATA cable routing and connectorsfrom the ServeRAID MR10i or ServeRAID MR10is controllers to eight 2
The following illustration shows the internal SAS power and signal cable routingfrom the hard disk drives to the connectors on the system board.1 SA
The following illustration shows the internal cable routing and connectors from theoperator information panel to the system board.1 Operator informa
Removing the air baffleTo remove the air baffle, do the following:1. Read the safety information that begins on page vii and “Installation guidelines”
Installing the air baffleTo install the air baffle, do the following:1. With the rear (hinged) part of the air baffle 3 lifted up, align the positio
Removing the fan-cage assembly1 Fan cage assembly2 Fan cage assembly release buttonsTo remove the fan-cage assembly, do the following:1. Read the
Installing the fan-cage assembly1 Fan cage assembly2 Fan cage assembly release buttonsTo install the fan-cage assembly, do the following:1. Align
6. Locate the battery on the system board (see “System-board internal connectors”on page 25).7. Remove the battery:a. Use one finger to push the batte
To install the replacement battery, do the following:1. Follow any special handling and installation instructions that come with thereplacement batter
Avis de conformité à la réglementation d’Industrie Canada ...187Australia and New Zealand Class A statement ...187United Kingdom telecomm
To remove a hot-swap power supply, do the following:1. Read the safety information “Safety” on page vii and “Handling static-sensitivedevices” on page
CAUTION:Never remove the cover on a power supply or any part that has the followinglabel attached.Hazardous voltage, current, and energy levels are pr
5. Connect one end of the power cord for the new power supply into the connectoron the back of the power supply; then, connect the other end of the po
1 Release latch2 Hot-swap power supply5. Remove the power supply filler from the second power supply bay.6. Slide the new power supply partially i
Removing a voltage regulator module1 Microprocessor 2 VRM2 Heat sink 23 VRM connectorTo remove a voltage regulator module (VRM), do the followin
Installing a voltage regulator module1 Microprocessor 2 VRM2 Heat sink 23 VRM connectorTo install a voltage regulator module, do the following:1
Removing the rear adapter retention bracket1 Rear adapter retention bracket2 Hinge pinTo remove the rear adapter-retention bracket, do the followi
Installing the rear adapter retention bracket1 Rear adapter retention bracket2 Hinge pinsTo install the rear adapter retention bracket, do the fol
Removing an adapter1 Rear adapter retention bracket2 Adapter3 Front adapter retention bracketTo remove an adapter, do the following:1. Read the
v Locate the documentation that comes with the adapter and follow thoseinstructions in addition to the instructions in this section. If you must chang
SafetyBefore installing this product, read the Safety Information.Antes de instalar este produto, leia as Informações de Segurança.Pred instalací toho
3. See the documentation that comes with the adapter for any cabling instructionsand information about jumper or switch settings. (It might be easier
Attention: Incomplete insertion might cause damage to the system board orthe adapter.8. Connect any needed cables to the adapter.If you have other dev
Installing a DVD (optical) driveTo install a DVD (optical) drive 1, do the following:1. Read the safety information that begins on page vii and “Ins
Removing an optional tape drive1 EMC shield2 Tape driveTo remove an optional tape drive, do the following:1. Read the safety information that begi
Installing a USB or SATA tape driveThe server supports USB and SATA tape drives. When you install a tape drive, besure to connect the internal tape ca
1 Fan-cage assembly release buttons2 Fan-cage assemblya. Press the fan-cage release latches on the top and bottom of the fan cagetoward the sides
14. If the tape drive came with screws, secure the drive to the server chassis,using the supplied screws.1 SATA optical drive power connector2 USB
Removing a 2.5-inch hot-swap hard disk drive1 Filler panel2 Hard disk drive assembly3 Release latch4 Drive handleTo remove a hot-swap hard dis
– On models with eight hard disk drives, the top bays are numbered 0 through 7(from right to left)– On models with 16 hard disk drives, the top bays a
1 Filler panel2 Hard disk drive assembly3 Release latch4 Drive handleTo install a hot-swap hard disk drive, do the following:1. Read the safet