Lenovo ThinkServer TD200 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Computerhardware Lenovo ThinkServer TD200 herunter. Lenovo ThinkServer TD200 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 228
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 1 - Installation and User Guide

Installation and User GuideThinkServer TD200Machine Types: 3724, 3808, 3809, 3815, 3817, 3824, 3826, and 3836

Seite 2

Important:All caution and danger statements in this documentation begin with a number. Thisnumber is used to cross reference an English caution or dan

Seite 3

1 Power supply retaining screws2 Power supply assembly7. If you are instructed to return the power supply, follow all packaging instructions,and u

Seite 4

1 Power supply retaining screws2 Power supply assembly2. While you support the power supply cage, install the three screws that securethe power su

Seite 5 - Contents

1 Power supply support bracket2 Power supply release tab5. Install the side cover (see “Installing the side cover” on page 134).6. Lock the side c

Seite 6

4. If you are instructed to return the hot-swap fan, follow all packaging instructions,and use any packaging materials that are supplied to you for sh

Seite 7 - Contents v

3. Press down on the fan until it locks into place; then, close the fan handle to thelocking position.4. Install the side cover (see “Installing the s

Seite 8

1 Power supply2 Power-supply handle6. Remove the air baffle (see “Removing the air baffle” on page 44).7. Locate the DIMM connector that contains

Seite 9

88 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Seite 10

1 DIMM 1 (reserved) 9 DIMM 9 (reserved)2 DIMM 2 10 DIMM 103 DIMM 3 11 DIMM 114 DIMM 4 (reserved) 12 DIMM 12 (reserved)5 DIMM 5 13

Seite 11 - Safety ix

supported options for the server, see http://www.lenovo.com/thinkserver; then,select your country and navigate to the list of options for the server.–

Seite 12

Note: The amount of usable memory is reduced depending on the systemconfiguration. A certain amount of memory must be reserved for systemresources. To

Seite 13 - Safety xi

Statement 1:DANGERElectrical current from power, telephone, and communication cables ishazardous.To avoid a shock hazard:v Do not connect or disconnec

Seite 14

The following table lists the installation sequence for installing DIMMs inmemory-mirroring mode.Table 9. Memory-mirroring mode DIMM population sequen

Seite 15 - Safety xiii

1 Power supply2 Power-supply handle4. Remove the air baffle (see “Removing the air baffle” on page 44).5. Locate the DIMM connectors on the system

Seite 16

8. Turn the DIMM so that the DIMM keys align correctly with the connector.1 DIMM2 Retaining clip9. Insert the DIMM into the connector by aligning

Seite 17 - Safety xv

1 Power supply support bracket2 Power supply release tab12. Install the side cover (see “Installing the side cover” on page 134).13. Lock the side

Seite 18

1 Rear adapter-retention bracket2 Adapter3 Front adapter-retention bracket8. If the adapter is not being replaced, install an expansion-slot cov

Seite 19 - Chapter 1. Introduction

for x4 and x8 adapters. These same rules apply to the other PCI slots also.Check the information that comes with your adapter for compatibility inform

Seite 20

Note: Do not allow the server to fall over.4. Follow the cabling instructions that come with the adapter to set jumpers orswitches, if there are any.

Seite 21 - Related documentation

1 Adapter2 Rear adapter retention bracket3 Front adapter retention bracket8. Connect all required cables to the adapter. Route cables so that th

Seite 22

v The first microprocessor must always be installed in microprocessor socket 1.v When one microprocessor is installed, a heat sink filler is not requi

Seite 23

1 DIMM 9 (reserved) 15 DIMM 22 DIMM 10 16 DIMM 1 (reserved)3 DIMM 11 17 Battery4 DIMM 12 (reserved) 18 PCI extender card connector5

Seite 24

Statement 2:CAUTION:When replacing the lithium battery, use only a battery recommended by themanufacturer. If your system has a module containing a li

Seite 25 - Features and technologies

4. Remove the air baffle (see “Removing the air baffle” on page 44).5. Remove the fan cage assembly (see “Removing the fan cage assembly” onpage 46).6

Seite 26

c. Rotate the microprocessor release latch on the microprocessor socket fromthe closed and locked position to the fully open position.Attention:v Do n

Seite 27 - Specifications

1 Thermal grease2 Heat sinka. Make sure that the heat-sink release lever is in the open position.b. Remove the plastic protective cover from the b

Seite 28

e. Tilt the heat sink slightly to the side and slide the heat sink flangeunderneath the flange of the heat sink retainer bracket.f. Press down firmly

Seite 29

5. Disconnect any cables connected to the adapter.Attention: To avoid breaking the retaining clips or damaging theServeRAID-BR10i adapter connector, o

Seite 30 - EasyManage

1 ServeRAID-BR10i controller2 PCI slot 18. Press the ServeRAID-BR10i adapter firmly into the connector on the systemboard.9. Rotate the power-supp

Seite 31

11. Remove the fan cage assembly (see “Removing the fan cage assembly” onpage 46).12. Connect the configuration signal cable. See “Power and signal ca

Seite 32

slots on the bottom of the chassis underneath the fan cage assembly; then,connect it to the ServeRAID-BR10i SAS/SATA controller as shown in thefollowi

Seite 33 - Front view

1 Adapter connector2 Signal cable14. Reinstall the front fan cage assembly. Align the front fan cage assembly overthe fan cage assembly slot and w

Seite 34

1 Power supply support bracket2 Power supply release tabIf you have other options to install or remove, do so now. Otherwise, Go to“Completing the

Seite 35 - 1 Power-on LED 6 USB 1

Statement 3:CAUTION:When laser products (such as CD-ROMs, DVD drives, fiber optic devices, ortransmitters) are installed, note the following:v Do not

Seite 36

Installing the optional ServeRAID-MR10i SAS/SATA controllerThe optional ServeRAID-MR10i SAS/SATA controller can be installed only in itsdedicated conn

Seite 37 - Operator information panel

1 ServeRAID adapter2 Battery carrier3 Battery4 Connector for battery carrierb. Press the battery carrier into the connector on the ServeRAID a

Seite 38 - EasyLED diagnostic panel

1 ServeRAID-MR10i controller2 PCI slot 110. Press the ServeRAID-MR10i adapter firmly into the connector on the systemboard.11. Rotate the power-su

Seite 39

1 Adapter connector for drives 0-3 signal cable2 Signal cable for drives 0-3The following illustration shows the connectors on the controller to w

Seite 40

1 Signal cables for drives 4-72 Adapter connector for drives 4-7 signal cable3 Signal cable for drives 0-34 Adapter connector for drives 0-3 s

Seite 41

1 Adapter connector2 Signal cable16. Reinstall the front fan cage assembly. Align the front fan cage assembly overthe fan cage assembly slot and w

Seite 42

1 Power supply support bracket2 Power supply release tab19. If you have other options to install or remove, do so now.20. Replace the side cover (

Seite 43

2. Turn off the server and peripheral devices, and disconnect the power cordsand all external cables.Attention: To avoid breaking the retaining clips

Seite 44 - Rear view

c. Secure the battery carrier to the ServeRAID adapter with the screws thatcame with the battery pack.10. Turn the ServeRAID-MR10is adapter so that th

Seite 45

1 Power supply2 Power-supply handle13. Remove the air baffle (see “Removing the air baffle” on page 44).14. Remove the front fan cage assembly (se

Seite 46

Statement 4:≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb)CAUTION:Use safe practices when lifting.Statement 5:CAUTION:The power control button

Seite 47

1 Adapter connector for drives 0-3 signal cable2 Signal cable for drives 0-3The following illustration shows the connectors on the controller to w

Seite 48

1 Signal cable for drives 4-72 Adapter connector for drives 4-7 signal cable3 Signal cable for drives 0-34 Adapter connector for drives 0-3 si

Seite 49

1 Adapter connector2 Signal cable17. Reinstall the front fan cage assembly. Align the front fan cage assembly overthe fan cage assembly slot and w

Seite 50

1 Power supply support bracket2 Power supply release tab21. If you have other options to install or remove, do so now.22. Replace the side cover (

Seite 51 - System-board LEDs

Do not insert a memory DIMM in this connector.This DIMM slot is not supported in this model.Do not insert a memory DIMM in this connector.This DIMM sl

Seite 52

Do not insert a memory DIMM in this connector.This DIMM slot is not supported in this model.Do not insert a memory DIMM in this connector.This DIMM sl

Seite 53 - Turning off the server

5. Rotate the power-supply cage assembly out of the chassis. Lift up thepower-supply cage handle and pull the power-supply cage assembly all theway up

Seite 54

9. Disconnect the control-panel assembly cable from the system board, noting therouting of the cable (see “System-board internal connectors” on page 2

Seite 55 - Installation guidelines

1 Power supply support bracket2 Power supply release tab8. Close the bezel.9. Install the side cover (see “Installing the side cover” on page 134)

Seite 56 - System reliability guidelines

1 Bezel2 Hinge assembly3 Retention tabs2. Push the hinges into the holes on the chassis until they snap into place.3. If however, the bezel was

Seite 57

Statement 8:CAUTION:Never remove the cover on a power supply or any part that has the followinglabel attached.Hazardous voltage, current, and energy l

Seite 58 - Opening the bezel

1 Sliding hinge mount2 Hinge pin3 Hinge assemblyb. Align the sliding hinge mount with the hinge pin on the hinge assembly onthe chassis.c. Press

Seite 59

1 Air baffle pinch tab2 Air baffle2. Lower the air baffle into the server until the air baffle is seated firmly.3. Press the power supply release

Seite 60

5. Lock the side cover.6. Reconnect the external cables and power cords; then, turn on the attacheddevices and turn on the server.Installing the side

Seite 61 - Removing the side cover

If the server cables and connector panel have color-coded connections, match thecolor of the cable end with the color of the connector. For example, m

Seite 62 - Removing the air baffle

Some options have device drivers that you must install. For information aboutinstalling device drivers, see the documentation that comes with each opt

Seite 63

Chapter 6. Configuring the serverThe following configuration programs and utilities come with the server:v Setup UtilityThe UEFI (formerly BIOS) Setup

Seite 64

v Advanced Settings Utility (ASU) programUse this program as an alternative to the Setup Utility for modifying UEFI settingsand IMM settings. Use the

Seite 65 - 1 Fan cage assembly

Select this choice to view the system-board identifier, the revision level orissue date of the firmware, the integrated management module anddiagnosti

Seite 66

specify whether to use the static IP address or have DHCP assign the IMMIP address; save the network changes.- Reset IMM to DefaultsSelect this choice

Seite 67

v User SecuritySelect this choice to set, change, or clear passwords. See “Passwords” for moreinformation.This choice is on the full and limited Setup

Seite 68

Statement 13:DANGEROverloading a branch circuit is potentially a fire hazard and a shock hazardunder certain conditions. To avoid these hazards, ensur

Seite 69

password has access to only the limited Setup Utility menu; the user can set,change, and delete the power-on password, if the system administrator has

Seite 70 - 2 Power-supply release tab

Table 11. RAID configuration utilities (continued)RAID configurationutility Description LocationWhere to find moreinformationMegaRAID BIOSConfiguratio

Seite 71 - 2 Hinge pins

v Hard disk drive capacities affect how you create arrays. The drives in an arraycan have different capacities, but the RAID controller treats them as

Seite 72 - Removing the battery

3. Select the type of array that you want to create.4. In the RAID Disk column, use the Spacebar or Minus (-) key to select [Yes](select) or [No] (des

Seite 73 - Installing the battery

Physical View or Logical ViewSelect this to toggle between the Physical View and Logical View.EventsFrom this view, you can display the system events

Seite 74 - 1 Positive (+) side

menu and click Change. The Operations panel lists operations that can beperformed on the virtual disk. Select the operation and click Go. Then choose

Seite 75

Configuring RAIDThe RAID configuration feature that is part of the EasyStartup program enables youto view and change RAID settings for supported RAID

Seite 76

You will then see one or more reminders about configuring storage devices, andthen you will be presented with the Lenovo License Agreement. Read the l

Seite 77 - Removing a DVD drive

v Install applications: This task enables you to run custom commands or scriptsat the end of the installation process. It also facilitates the install

Seite 78

Enabling the Broadcom Gigabit Ethernet Utility programThe Broadcom Gigabit Ethernet Utility program is part of the server firmware. Youcan use it to c

Seite 79

Statement 26:CAUTION:Do not place any object on top of rack-mounted devices.This server is suitable for use on an IT power-distribution system whose m

Seite 80 - Installing a DVD drive

3. From Family list, select ThinkServer TD200, and click Continue.4. Click Downloads and drivers to download firmware updates.Download the latest firm

Seite 81

To download the server firmware update package from the World Wide Web, do thefollowing:Note: Changes are made periodically to the Lenovo Web site. Th

Seite 82 - 3 Optical drive rails

6. Reinstall the server cover (see “Installing the side cover” on page 134); then,reconnect all power cords.7. Restart the server. The power-on self-t

Seite 83 - 1 Optical drive power cable

2. Remove any devices that you added recently and restart the server.3. If the problem remains, go to the Setup utility and select Load DefaultSetting

Seite 84

v Boot sequence manipulation.The IMM also provides the following remote server management capabilities:v Command-line interface (IPMI Shell)The comman

Seite 85

1. Install the virtual media key into the dedicated slot on the system board (see“System-board option connectors” on page 30).2. Turn on the server.No

Seite 86 - 2 Tape drive

Diagnostics programs and messagesThe diagnostics programs are the primary method of testing the major componentsof the server. As you run the diagnost

Seite 87

Note: The DSA Preboot diagnostics program might appear to be unresponsivefor an unusual length of time when you start the program. This is normalopera

Seite 88

Installing EasyManage softwareYou can install the ThinkServer™EasyManage Core Server program from theEasyManage CD or you can download and install the

Seite 89 - 4 Hard disk drive

Note: This specific version is required.6. Use Windows Update to install all available critical updates.7. Launch the EasyManage installation.8. After

Seite 90 - 5 Hard disk drive

xvi ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Seite 91

v Static Contentv ASP.NETv ASPv CGIv Server Side Includesv Windows Authenticationv IIS 6 Metabase CompatibilityNote: When you select ASP.Net or ASP, a

Seite 92

Chapter 7. TroubleshootingThis chapter describes the diagnostic tools that are available to help you solveproblems that might occur in the server.If y

Seite 93

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 94 - 2 Drive-bay EMC shield

General problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardwar

Seite 95

Intermittent problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Ha

Seite 96

Memory problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware

Seite 97 - Removing a power supply

Microprocessor problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the

Seite 98

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 99

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 100 - Installing a power supply

Power problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware

Seite 101 - 2 Power supply assembly

Chapter 1. IntroductionThis Installation and User Guide contains information and instructions for setting upyour ThinkServer TD200 Types 3724, 3808, 3

Seite 102 - Removing a hot-swap fan

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 103 - Installing a hot-swap fan

Software problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardwa

Seite 104 - Removing a memory module

clear the CMOS memory; see “System-board switches and jumpers” on page 31. Ifyou suspect that the server firmware is damaged, see “Recovering the serv

Seite 105 - 2 Power-supply handle

1. Make sure that external SCSI devices are turned on before you turn on theserver.2. Make sure that the cables for all external SCSI devices are conn

Seite 106

– The Ethernet transmit/receive activity LED is lit when the Ethernet controllersends or receives data over the Ethernet network. If the Ethernettrans

Seite 107 - Installing a memory module

v Integrated management module (IMM) event log: This log contains a supersetof IMM, POST, and systems-management interrupt (SMI) information that is i

Seite 108 - 12 Dual-rank DIMMs 4 GB 48 GB

Table 12. Methods for viewing event logsCondition ActionThe server is not hung and is connected to anetwork.Run Portable or Installable DSA to view th

Seite 109

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 110

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 111

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 113 - Removing an adapter

The model number and serial number are on the lower right side of the bezel. 1Note: The illustrations in this document might differ slightly from yo

Seite 114 - Installing an adapter

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 115

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 116

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 117 - 1 Adapter

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 118

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 119

Appendix A. Getting help and technical assistanceIf you need help, service, or technical assistance or just want more informationabout Lenovo products

Seite 120

Calling for serviceDuring the warranty period, you can get help and information by telephone throughthe Customer Support Center.These services are ava

Seite 121 - 3 Notches

Service methods and procedures vary by country, and some services might not beavailable in all countries. International Warranty Service is delivered

Seite 122

190 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Seite 123 - 2 Power supply release tab

Appendix B. NoticesLenovo may not offer the products, services, or features discussed in this documentin all countries. Consult your local Lenovo repr

Seite 124

v Danger: These statements indicate situations that can be potentially lethal orextremely hazardous to you. A danger statement is placed just before t

Seite 125 - 2 PCI slot 1

estimated through extrapolation. Actual results may vary. Users of this documentshould verify the applicable data for their specific environment.Trade

Seite 126

Maximum memory might require replacement of the standard memory with anoptional memory module.Lenovo makes no representations or warranties with respe

Seite 127

Remarque : Cette marque s’applique uniquement aux pays de l’Union Européenneet à la Norvège.L’etiquette du système respecte la Directive européenne 20

Seite 128 - 2 Signal cable

Recycling statements for JapanBattery return programThis product may contain a lithium or lithium ion battery. Consult your user manualor service manu

Seite 129

For the European Union:Notice: This mark applies only to countries within the European Union (EU).Batteries or packaging for batteries are labeled in

Seite 130

Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne§2derBildschirmarbeitsverordnung geeignet.Electronic emission noticesFederal

Seite 131 - 3 Battery

failure to satisfy the protection requirements resulting from a non-recommendedmodification of the product, including the fitting of non-Lenovo option

Seite 132

Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022Klasse A.Nach der EN 55022: “Dies ist eine Einrichtung der Klasse A. Diese Einrich

Seite 133

Korea Class A warning statement200 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Seite 134

IndexAABR, automatic boot failure recovery 154acoustical noise emissions 9, 11adapterhot-plug devices 106installing 97hot-plug 106removing 95requireme

Seite 135

4 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Seite 136

Ddanger statements 2DASD LED 22data rate, Ethernet 151deassertion event, system-event log 176diagnostics program 8DIMM installation sequencefor memory

Seite 137

firmware updates 1firmware, serverstarting the backup 152firmware, server, recovering 152firmware, updating 151formattinghard disk drive 144front USB

Seite 138

LEDsDVD drive activity 18EasyLED; diagnostics 25Ethernet link status 27Ethernet transmit/receive activity 27hard disk drive activity 17hot-swap hard d

Seite 139

password, power-onclear 141set 141passwords 141PCIbus LED 21PCI extender cardone-slot 34two-slot 34pointing-device problems 166portsEthernet 27serial

Seite 140

safety information (continued)Statement 3 xiStatement 4 xiiStatement 5 xiiStatement 8 xiiisystem reliability considerations 38when the server is on 38

Seite 141

TÜV gloss statement 196two-slotPCI extender card 34UUEFIboot recovery jumper 153UEFI update failurerecovery 152undetermined problems 173United States

Seite 142

208 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Seite 144 - 4 Retention tab

Part Number: 44W2344Printed in USA(1P) P/N: 44W2344

Seite 145

Chapter 2. Server setup roadmapThe installation process varies depending on the configuration of the server when itwas delivered. In some cases, the s

Seite 146

6 ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide

Seite 147 - 2 Control panel assembly

Chapter 3. What is included with your serverThe TD200 server package includes the server, power cords, and the ThinkServerDocumentation DVD.1 Server

Seite 148 - Closing the bezel

Note: The server does not support Disk Operating System (DOS).v Preboot diagnostics programThe preboot diagnostics programs are stored on the integrat

Seite 149 - 3 Retention tabs

Some models support memory mirroring. Memory mirroring replicates and storesdata on two pairs of DIMMs within two channels (channel 0 and 1)simultaneo

Seite 150 - Installing the air baffle

Table 1. Features and specificationsMicroprocessor:v Supports up to two Intel®Pentium®dual-core or quad-core microprocessors(one installed) with integ

Seite 151 - 2 Air baffle

Table 1. Features and specifications (continued)Drives (depending on the model):v Optical drives: SATAv Hard disk drives: SAS and SATADrive bays (depe

Seite 152 - Connecting the cables

ThinkServer TD200 Types 3724, 3808, 3809, 3815,3817, 3824, 3826, 3836Installation and User Guide

Seite 153

Table 1. Features and specifications (continued)Up to eight expansion slots (dependingon the model):v Six expansion slots on the systemboard– Four PCI

Seite 154 - Connecting external devices

Reliability, availability, and serviceabilityThree important server design features are reliability, availability, and serviceability(RAS). The RAS fe

Seite 155

v Upgradeable microcode for POST, server firmware, and read-only memory(ROM) resident code, locally or over a LANv Vital product data (VPD); includes

Seite 156 - Setup Utility menu choices

Chapter 4. Server controls, LEDs, and powerThis section describes the controls, light-emitting diodes (LEDs), and connectors onthe front and rear of t

Seite 157

1 Power-on LED 7 DVD-eject button2 Power-control button 8 Hard disk drive activity LED (green)3 Hard disk drive activity LED 9 Hard disk d

Seite 158

1 Power-on LED 6 USB 12 Power-control button 7 DVD-eject button3 Hard disk drive activity LED 8 Simple-swap hard disk drive4 System-erro

Seite 159 - Passwords

An LED on the system board might also be lit to help isolate the error.Detailed troubleshooting information is in the Hardware MaintenanceManual.USB c

Seite 160 - Configuring RAID controllers

Operator information panelThe following illustration shows the LEDs on the operator information panel on thefront of the server.1 System power-on LE

Seite 161

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 162 - Formatting a hard disk drive

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 163 - Starting the WebBIOS utility

Note:Note: Before using this information and the product it supports, read the general information in Appendix B, “Notices,” on page 191and the Warran

Seite 164

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 165 - Using the EasyStartup DVD

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 166 - EasyStartup overview

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 167

v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the Hardware Maintenance Ma

Seite 168

Rear viewThe following illustration shows the LEDs and connectors on the rear of the server.1 Power cord connector 10 USB 12 Ethernet transmit/r

Seite 169 - Updating the firmware

Power-error (Fault) LEDWhen this amber LED is lit, it indicates that the power supply has failed.For any other combination of LEDs, see the Hardware M

Seite 170

System-board internal connectorsThe following illustration shows the internal connectors on the system board.1 Main power 12 Reserved2 Reserved

Seite 171 - 3 SW6 switch block

System-board external connectorsThe following illustration shows the external input/output (I/O) connectors on thesystem board.1 Power connector 6

Seite 172 - Three boot failure

System-board option connectorsThe following illustration shows the system-board connectors for user-installableoptions.1 DIMM 9 (reserved) 15 DIMM

Seite 173

System-board switches and jumpersThe following illustration shows the switches and jumpers on the system board.1 UEFI boot recovery jumper (JP8)2

Seite 174

ContentsSafety ...viiChapter 1. Introduction ...1Notices and statements in this document...2R

Seite 175

Table 2. System-board jumpers (continued)Jumper number Jumper name Jumper settingJP6 UEFI boot recovery jumperv Pins 1 and 2: Normal(default) - Loads

Seite 176

Important:1. Before you change any switch settings or move any jumpers, turn off the server,then, disconnect all power cords and external cables. Read

Seite 177

1 Microprocessor mismatchLED9 PCI slot 6 error LED2 Microprocessor 2 error LED 10 PCI slot 5 error LED3 DIMMs 9-18 error LEDs 11 PCI slot

Seite 178 - Installation order

Server power featuresWhen the server is connected to an ac power source but is not turned on, theoperating system does not run, and all core logic exc

Seite 179

12The server can be turned off in any of the following ways:v You can turn off the server from the operating system, if your operating systemsupports

Seite 180

Chapter 5. Installing optional devices and replacing customerreplaceable unitsImportant: Before you install optional hardware, make sure that the serv

Seite 181 - Chapter 7. Troubleshooting

v You do not have to turn off the server to install or replace hot-swap fans andhot-swap drives.v Blue on a component indicates touch points, where yo

Seite 182 - Diskette drive problems

v Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wristwatches.v Remove items from your shirt pocket, such as pens and pencils,

Seite 183 - Hard disk drive problems

Major components of the serverThe following illustration shows the major components in the server (depending onthe server model). The illustrations in

Seite 184 - Intermittent problems

Note: You must unlock the side cover to open or remove the bezel. When youlock the server side cover, it locks both the cover and the bezel.3. Remove

Seite 185 - Memory problems

Removing and installing drives ...57Removing a DVD drive ...59Installing a DVD drive ...62Removing

Seite 186 - Monitor or video problems

1 Bezel2 Hinge assembly3 Retention tabsNote: The bezel will also disengage from the chassis hinges if you rotate thebezel beyond 180° or if exce

Seite 187

4. From inside of the top section of the bezel door, slide the blue tab up to unlockthe bezel media door (slide the tab down when you want to lock it)

Seite 188 - Optional-device problems

1 Cover release latch2 Latch3 Left-side coverTo replace the side cover, see “Installing the side cover” on page 134.Attention: For proper coolin

Seite 189 - Power problems

1 Power supply2 Power-supply handle8. Remove the air baffle assembly. Press the blue tab (on top of the fan cage) onthe air baffle assembly to the

Seite 190 - Serial port problems

Removing the fan cage assemblyAttention:v Replace a hot-swap fan within 30 seconds of removal.v To ensure proper cooling and airflow, do not operate t

Seite 191 - Solving undetermined problems

1 Fan cage assembly2 Fan cage assembly release buttons8. If you are instructed to return the fan cage, follow all packaging instructions, anduse a

Seite 192 - Solving SCSI problems

1 Fan cage assembly2 Fan cage assembly release buttons2. Slide the fan cage into the chassis and press firmly until the fan cage is seatedfirmly i

Seite 193 - Solving power problems

1 Power supply support bracket2 Power supply release tab5. Install the side cover (see “Installing the side cover” on page 134).6. Lock the side c

Seite 194 - Event logs

1 Power supply2 Power-supply handle5. Remove the air baffle (see “Removing the air baffle” on page 44).6. Remove the fan cage assembly (see “Remov

Seite 195

9. Press the release tab on the front USB housing; then, tilt the top of thehousing away from the chassis and lift the housing out of the chassis.10.

Seite 196 - POST error codes

EasyStartup overview ...148Installing your operating system without using EasyStartup ...150Using the Boot Manager program ...

Seite 197

6. Install the fan cage assembly (see “Installing the fan cage assembly” on page47).Note: Make sure that all cables are routed so that they are not da

Seite 198

4. Open the rear adapter retention bracket.5. Press the rear adapter retention bracket and release the top hinge point; then,release the other hinge p

Seite 199

4. Install the side cover (see “Installing the side cover” on page 134).5. Lock the side cover, if necessary.6. Reconnect the external cables and powe

Seite 200

Statement 2:CAUTION:When replacing the lithium battery, use only a battery recommended by themanufacturer. If your system has a module containing a li

Seite 201

v The lithium battery must be handled correctly to avoid possible danger. If youreplace the battery, you must adhere to the following instructions.v Y

Seite 202

Note: You must wait approximately 1 to 3 minutes after you connect the powercord of the server to an electrical outlet before pressing the power-contr

Seite 203

1 Bay 12 Bay 23 Bay 34 Bay 45 Bay 56 Bay 67 Bay 7The following illustration shows the location of the drive bays in the 3.5-inchsimple-s

Seite 204

1 Bay 12 Bay 23 Bay 34 Bay 45 Bay 56 Bay 67 Bay 7The following notes describe the types of drives that the server supports and otherinfo

Seite 205 - Using the documentation

1. Read the safety information (see “Safety” on page vii and “Installationguidelines” on page 37).2. Turn off the server and all attached devices; the

Seite 206 - Using other services

1 Fan cage assembly2 Fan cage assembly release buttons8. Disconnect the power and signal cables from the drive that is to be removed.9. Press and

Seite 207 - Lenovo product service

Lenovo product service ...189Appendix B. Notices ...191Trademarks...192Important notes ...

Seite 208

Installing a DVD driveTo install a DVD drive, do the following:1. If you are replacing a drive, make sure that:v You have all the cables and other equ

Seite 209 - Appendix B. Notices

1 Power supply2 Power-supply handle3. Remove the air baffle (see “Removing the air baffle” on page 44).4. Remove the fan cage assembly. Press in o

Seite 210 - Important notes

5. Touch the static-protective package that contains the new DVD drive to anyunpainted metal surface on the server; then, remove the DVD drive from th

Seite 211 - Appendix B. Notices 193

1 Optical drive power cable2 SATA optical drive signal cable10. Install the fan cage assembly (see “Installing the fan cage assembly” on page47).1

Seite 212 - Hazardous Substances

1 Power supply support bracket2 Power supply release tab13. Close the bezel.14. Install the side cover (see “Installing the side cover” on page 13

Seite 213 - Battery return program

and set it aside.8. Disconnect the tape drive cable from the system board.9. Remove the screws that secure the tape drive 1 to the server.10. Gently

Seite 214

1 EMC shield2 Tape drive5. If the tape drive comes with screws, secure the tape drive to the chassis withthe supplied screws.6. Connect one of the

Seite 215 - Appendix B. Notices 197

1 SATA optical drive power cable2 USB signal cable connector3 USB signal cable4 SATA optical drive power cable (SATA-to-traditional power conv

Seite 216

Removing a 2.5-inch hot-swap hard disk driveAttention: To maintain proper system cooling, do not operate the server for morethan 10 minutes without ei

Seite 217 - Appendix B. Notices 199

1 Release latch2 Drive tray handle (in open position)3 Drive tray4 Hard disk drive7. If you are instructed to return the 2.5-inch hot-swap har

Seite 218

SafetyBefore installing this product, read the Safety Information.Antes de instalar este produto, leia as Informações de Segurança.Pred instalací toho

Seite 219

1. Read the safety information (see “Safety” on page vii and “Installationguidelines” on page 37).2. Touch the static-protective package that contains

Seite 220

Removing a 3.5-inch hot-swap hard disk driveAttention: To maintain proper system cooling, do not operate the server for morethan 10 minutes without ei

Seite 221 - Index 203

1 Hot-swap hard disk drive2 Drive tray3 Drive tray handle (in open position)6. If you are instructed to return the 3.5-inch hot-swap hard disk d

Seite 222

6. Check the hard disk drive status indicator to make sure that the hard disk driveis operating correctly.After you replace a failed hard disk drive,

Seite 223 - Index 205

1 Filler panels2 Drive-bay EMC shield3 Tab4 Hard disk drive6. Pull the loops of the drive assembly that is to be removed toward each other;the

Seite 224

1 Filler panels2 Drive-bay EMC shield3 Tab4 Hard disk drive3. Pull the loops of the drive assembly toward each other; then, carefully slide th

Seite 225 - Index 207

Table 4. IDs for the four-bay 3.5-inch hot-swap drive models (continued)Drive bay number IDDrive bay 5 1Drive bay 6 2Drive bay 7 3Table 5. IDs for the

Seite 226

– The 2.5-inch hot-swap SAS and hot-swap SATA models come with thefollowing cables to provide signal and power to the hot-swap SAS/SATAdrives:- Two si

Seite 227

CAUTION:Never remove the cover on a power supply or any part that has the followinglabel attached.Hazardous voltage, current, and energy levels are pr

Seite 228 - (1P) P/N: 44W2344

1 Power supply2 Power-supply handle5. Disconnect the cables from the power supply to the system board and allinternal components. Be sure to make

Kommentare zu diesen Handbüchern