Lenovo Secure Managed Client Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Computerhardware Lenovo Secure Managed Client herunter. Lenovo Secure Managed Client User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Machine Type 8332

Secure Managed Client - Storage ArrayHardware Installation and Replacement GuideMachine Type 8332

Seite 2

2 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide

Seite 3 - Gui d e

Chapter 2. Overview This guide contains information about replacing Customer Replaceable Units (CRUs). This guide does not include proc

Seite 4

4 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide

Seite 5 - Contents

Chapter 3. Hardware installations and upgrades This chapter provides instructions for removing, installing, and replacing storage system

Seite 6

Removing and installing the enclosure cover To remove and install the enclosure cover, do the following: CAUTION: The enclosure cover

Seite 7 - Figures

Installing the enclosure cover To install the enclosure cover, do the following: CAUTION: Be sure to secure the enclosure cover to

Seite 8

Removing and installing the processor air duct To remove and install the processor air duct, do the following:Important: Always oper

Seite 9

6. If removing a processor air duct as part of another procedure, continue with that procedure.Installing the processor air duct T

Seite 10

Replacing a module Attention: Never leave an empty bay or slot in the rear of the enclosure after removing a module. Either insta

Seite 11 - Chapter 2. Overview

Attention: v Before performing any maintenance on the system, back up the data. Follow the instructions in the Secure Managed Cl

Seite 13 - Planning your installation

Installing a power supply unit To install a replacement PSU, do the following: DANGERDo not remove the covers from a PSU. Danger

Seite 14

2. Check for damage to the new PSU, especially to the rear connector on the module. 3. Slide the PSU into the mounting cage.

Seite 15

Connecting the power cord(s) To connect the power cords, do the following: Attention: Power connection must always be disconnected

Seite 16

Replacing a cooling fan The SMC - Storage Array has ten fans in its cooling cage to ensure proper cooling of the system. Each co

Seite 17

4. Inspect the new fan for any damage. Do not install it if there are any visible signs of damage. 5. Install the fan by pu

Seite 18 - Replacing a module

Removing and installing a drive carrier module To remove and install a drive carrier module, do the following: CAUTION: Observe all

Seite 19

4. Carefully remove the drive carrier module approximately 1 inch (25 mm) and wait 30 seconds before proceeding. 5. After 30 s

Seite 20

Installing a drive carrier module To install a drive carrier module, do the following: CAUTION: Ensure that all drive carriers are

Seite 21

5. Push the drive carrier until the foot on the base of the drive carrier engages with the enclosure. Continue to push firmly

Seite 22 - Grounding checks

Note: Do not turn the lock more than half a turn; otherwise, the drive carrier may be damaged. 3. Remove the screwdriver.De-acti

Seite 23 - Replacing a cooling fan

Secure M anaged Client - Sto rag e Array Hard ware Installation and Replacement Gui d e

Seite 24

4. If replacing the hard disk drive, see “Installing a hard disk drive into a drive carrier” for instructions on installing a h

Seite 25

5. For instructions on re-installing the drive carrier into the drive bay, see “Installing a hard disk drive into a drive carrie

Seite 26

9. Re-install the processor air duct. For instructions, see “Installing the processor air duct” on page 9. 10. Re-install the en

Seite 27

Table 1. (continued) 4 DIMM_B2 8 DIMM_D2 7. Make sure the clips at each end of the DIMM socket are pushed outward to the

Seite 28

4. Remove the enclosure cover. For instructions, see “Removing the enclosure cover” on page 6. 5. Remove the adapter bracket re

Seite 29

DANGERBatteries can explode if incorrectly replaced. Replace only with the same or equivalent type recommended by the equipment manuf

Seite 30

14. Run the BIOS Setup utility to restore the configuration settings to the real-time clock.Replacing the SAS expander PCB To repl

Seite 31 - Removing FBDIMMs

6. Insert the replacement SAS Expander PCB and plug the assembly into the backplane (see 1 in the following figure). Attach th

Seite 32 - Installing FBDIMMs

Intel RAID Controller SRCSATAWB up and out of the PCI slot (see 3). 6. Install the replacement Intel RAID Controller SRCSATAWB

Seite 33 - Removing an Ethernet card

7. Re-install the enclosure cover. For instructions, see “Installing the enclosure cover” on page 7. 8. Reconnect all peripheral

Seite 34 - Replacing a CMOS battery

Note Before using this information and the product it supports, be sure to read and understand the Safety and Warranty Guide for t

Seite 35

2). 7. Remove the single screw (see 1 in the following figure) at the top of the boot drive module and slide the module

Seite 36

9. Install lower boot drive in boot drive module with circuit side facing down and connectors oriented toward backplane (see 1

Seite 37 - RAID Controller SRCSATAWB

11. Align backplane screw holes with screw holes on boot drive module. Ensure backplane connectors are aligned with the drive con

Seite 38

13. Connect data cable(s) to the server board as follows: v Bottom boot drive to SAS 0 on server board v Top boot drive to

Seite 39

15. Align the two holes at the back of the boot drive module with the two chassis pins. Push until seated properly. Secure the

Seite 40

17. Re-install the processor air duct. For instructions, see “Installing the processor air duct” on page 9. 18. Re-install the e

Seite 41

38 Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide

Seite 42

Appendix A. Server board connector and header locations The following figure identifies server board connector and header locations.

Seite 43

13System fan 6 header 28USB header 43Front control panel header 14System fan 5 header 29IDE connector 44Serial B/emergency

Seite 44

Appendix B. Notices Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult yo

Seite 45

Contents Figures . . . . . . . . . . . . . . .v Chapter 1. Important safety information 1 Chapter 2. Overview . . . . .

Seite 46

vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measuremen

Seite 48

Part Number: 45K1344 Printed in USA (1P) P/N: 45K1344

Seite 49 - Appendix B. Notices

iv Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide

Seite 50 - Trademarks

Figures 1. Unlatching enclosure cover . . . . . . . .6 2. Removing enclosure cover . . . . . . . .7 3. Installing en

Seite 51

vi Secure Managed Client (SMC) - Storage Array Hardware Installation and Replacement Guide

Seite 52 - (1P) P/N: 45K1344

Chapter 1. Important safety information CAUTION: Before using this manual, it is important that you read and understand all the rela

Kommentare zu diesen Handbüchern

Keine Kommentare