Diagnostic Error Code FRU/Action
025-198-XXX
IDE interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Flash the system and re-test. See “Flash
update procedures” on page 111
3. Go to “Undetermined problems” on page
78
025-199-XXX
IDE interface test failed, cause unknown
1. Go to “Undetermined problems” on page
78
2. Flash the system and re-test. See “Flash
update procedures” on page 111
3. Replace component under function test
030-000-XXX
SCSI interface Test Passed
No action
030-00X-XXX
030-01X-XXX
SCSI interface failure
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-027-XXX
SCSI interface Configuration/Setup error
1. SCSI signal cable
2. Flash the system. See “Flash update
procedures” on page 111
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-03X-XXX
030-04X-XXX
SCSI interface error
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-195-XXX
SCSI interface Test aborted by user
Information only
Re-start the test, if necessary
030-196-XXX
SCSI interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
030-197-XXX
SCSI interface test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
66 Lenovo E200 Hardware Maintenance Manual