Diagnostic Error Code FRU/Action
011-197-XXX
Serial port test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
011-198-XXX
Serial port test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Flash the system and re-test. See “Flash
update procedures” on page 111
3. Go to “Undetermined problems” on page
78
011-199-XXX
Serial port test failed, cause unknown
1. Go to “Undetermined problems” on page
78
2. Flash the system and re-test. See “Flash
update procedures” on page 111
3. Replace component under function test
011-2XX-XXX
Serial port signal failure
1. External serial device
2. System board
014-000-XXX
Parallel port Interface Test Passed
No action
014-001-XXX
Parallel port Presence
1. Remove external parallel device, if
present
2. Run setup, enable port
3. System board
014-002-XXX
014-003-XXX
Parallel port Timeout/Parity error
System board
014-013-XXX
014-014-XXX
Parallel port Control Signal/Loopback test
failure
System board
014-015-XXX
Parallel port External Loopback failure
1. Wrap plug
2. System board
014-027-XXX
Parallel port Configuration/Setup error
1. Run Setup, enable port
2. Flash the system. See “Flash update
procedures” on page 111
3. System board
014-03X-XXX
014-04X-XXX
Parallel port failure
System board
014-195-XXX
Parallel port Test aborted by user
Information only
Re-start the test, if necessary
Chapter 7. Symptom-to-FRU Index 61